Tilt sensor - N6 static - N6SAU702V1-002 - Deutsch - ±60 | elostore
Tilt sensor - N6 static - N6SAU702V1-002 - Deutsch - ±60
Tilt sensor - N6 static - N6SAU702V1-002 - Deutsch - ±60
N6SAU702V1-002
  • Product details
  • Technical Data

Tilt sensor - N6 static - N6SAU702V1-002 - Deutsch - ±60

Part number: Art. -No. N6SAU702V1-002

per item €252.00

out of stock, deliverable in 60 working days

Quantity Price
from 5 pcs. €239.40 - 5 %
from 10 pcs. €221.45 - 12 %
from 25 pcs. €199.30 - 21 %
from 50 pcs. €179.37 - 29 %
from 100 pcs. €161.43 - 36 %
Compare variants
Create offer

out of stock, deliverable in 60 working days

Product information
Country of origin D
Customs tariff number 90318020
New N7 dynamic tilt sensor generation

Thanks to its high precision, the N6 static is ideal for use in static systems or with slow machine movements.
The sensors continuously monitor the angle of inclination of an object relative to gravity and thus provide reliable information for the safe control and movement of the mobile machine. They use MEMS (microelectromechanical systems).
 The field of application for inclination sensors ranges from agricultural and construction machinery to industrial trucks. The N6 static is particularly suitable for static machines such as multi-purpose compactors and lifting platforms. The available connector variants offer a suitable solution for every requirement.
Features
  • Precise and continuous measurement of the tilt angle of mobile machinery
  • Robust design for a long service life: protection class IP67 / IP69K [ISO 20653)
  • Simple variant management thanks to clever modular system
  • Up to 30% faster installation than with existing inclination sensors thanks to efficient 2-point mounting
Technical Data
N6SAI100V2-001
€270.00
N6SAI102H2-001
€252.00
N6SAI102H2-002
€252.00
N6SAI102H2-003
€252.00
N6SAI102H2-004
€252.00
N6SAI102H2-005
€252.00
N6SAI102H2-006
€252.00
N6SAI102H2-007
€252.00
N6SAI102V1-001
€252.00
N6SAI102V1-002
€252.00
N6SAI102V1-003
€252.00
N6SAI102V1-004
€252.00
N6SAI102V1-005
€252.00
N6SAI102V2-002
€252.00
N6SAI102V2-003
€252.00
N6SAI102V2-004
€252.00
N6SAI102V3-001
€252.00
N6SAI1D2H2-001
€270.00
N6SAU700V1-001
€270.00
N6SAU702H2-001
€252.00
N6SAU702H2-002
€252.00
N6SAU702H2-003
€252.00
N6SAU702H2-004
€252.00
N6SAU702H2-005
€252.00
N6SAU702H2-006
€252.00
N6SAU702H2-007
€252.00
N6SAU702H2-008
€252.00
N6SAU702V1-001
€252.00
N6SAU702V1-002
€252.00
N6SAU702V2-001
€252.00
N6SAU702V2-002
€252.00
N6SAU702V2-003
€252.00
N6SAU702V2-004
€252.00
N6SAU702V2-005
€252.00
N6SAU702V2-006
€252.00
N6SAU702V3-001
€252.00
Electrical data
Angle measuring range - analogue output: X-axis: ±45°<br>Y-axis: ±45° X-axis: ±5°<br>Y-axis: ±5° X-axis: ±10°<br>Y-axis: ±10° X-axis: ±15°<br>Y-axis: ±15° X-axis: ±20°<br>Y-axis: ±20° X-axis: ±25°<br>Y-axis: ±25° X-axis: ±30°<br>Y-axis: ±30° X-axis: ±45°<br>Y-axis: ±45° Z-axis: ±15° Z-axis: ±20° Z-axis: ±30° Z-axis: ±50° Z-axis: ±60° X-axis: ±20°<br>Z-axis: ±20° X-axis: ±30°<br>Z-axis: ±30° X-axis: ±10°<br>Z-axis: ±10° X-axis: ±10° X-axis: ±15°<br>Y-axis: ±15° Z-axis: ±30° X-axis: ±5°<br>Y-axis: ±5° X-axis: ±10°<br>Y-axis: ±10° X-axis: ±15°<br>Y-axis: ±15° X-axis: ±20°<br>Y-axis: ±20° X-axis: ±25°<br>Y-axis: ±25° X-axis: ±30°<br>Y-axis: ±30° X-axis: ±60°<br>Y-axis: ±60° X-axis: ±10°<br>Y-axis: ±30° Z-axis: ±25° Z-axis: ±60° X-axis: ±10°<br>Z-axis: ±10° X-axis: ±20°<br>Z-axis: ±20° X-axis: ±25°<br>Z-axis: ±25° X-axis: ±30°<br>Z-axis: ±30° X-axis: ±40°<br>Z-axis: ±40° X-axis: ±45°<br>Z-axis: ±45° X-axis: ±120°
Connection type (switching output): - - - - - - - - - - - - - - - - - Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = - - - - - - - - - - - - - - - - - - -
Contact form: - - - - - - - - - - - - - - - - - NC - - - - - - - - - - - - - - - - - -
Current consumption: < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA
EMC Agricultural and forestry machines (Norm): EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982 Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 14 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm): DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1 Load dump Pulse B wiht Us = 85V, Cranking ISO 16750-2 Level 14 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm): DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895
Function error output signal: 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 22mA 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V 5V
Hysteresis: - - - - - - - - - - - - - - - - - ±0,1° - - - - - - - - - - - - - - - - - -
Initialisation time after power on/start-up time: 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms
Limit frequency: 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz 20Hz
Linearity error: max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich max. 1% vom Messbereich
Load resistance: UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm 1-47 kOhm
MTTF: 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a 76 a
Max. switching current: - - - - - - - - - - - - - - - - - 1 A - - - - - - - - - - - - - - - - - -
Max. switching power: - - - - - - - - - - - - - - - - - 30 W - - - - - - - - - - - - - - - - - -
Max. switching voltage: - - - - - - - - - - - - - - - - - 36 V DC - - - - - - - - - - - - - - - - - -
Measuring principle: (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements) (quasi-) static (non-moving applications / slow movements)
Measuring range: ±45° X-Achse<br>±45° Z-Achse ±5° X-Achse<br>±5° Y-Achse ±10° X-Achse<br>±10° Y-Achse ±15° X-Achse<br>±15° Y-Achse ±20° X-Achse<br>±20° Y-Achse ±25° X-Achse<br>±25° Y-Achse ±30° X-Achse<br>±30° Y-Achse ±45° X-Achse<br>±45° Y-Achse ±15° Z-Achse ±20° Z-Achse ±30° Z-Achse ±50° Z-Achse ±60° Z-Achse ±20° X-Achse<br>±20° Z-Achse ±30° X-Achse<br>±30° Z-Achse ±10° X-Achse<br>±10° Z-Achse ±10° X-Achse ±15° X-Achse<br>±15° Y-Achse ±30° Z-Achse ±5° X-Achse<br>±5° Y-Achse ±10° X-Achse<br>±10° Y-Achse ±15° X-Achse<br>±15° Y-Achse ±20° X-Achse<br>±20° Y-Achse ±25° X-Achse<br>±25° Y-Achse ±30° X-Achse<br>±30° Y-Achse ±60° X-Achse<br>±60° Y-Achse ±10° X-Achse<br>±30° Y-Achse ±25° Z-Achse ±60° Z-Achse ±10° X-Achse<br>±10° Z-Achse ±20° X-Achse<br>±20° Z-Achse ±25° X-Achse<br>±25° Z-Achse ±30° X-Achse<br>±30° Z-Achse ±40° X-Achse<br>±40° Z-Achse ±45° X-Achse<br>±45° Z-Achse ±120° X-Achse
Measuring range acceleration max.: ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g 8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g
Measuring range gyroscope max.: ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s 250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s
Number of measurement axes (Number): 2 2 2 2 2 2 2 2 1 1 1 1 1 2 2 2 1 2 1 2 2 2 2 2 2 2 2 1 1 2 2 2 2 2 2 1
Number of measurement axes tilt: 2 2 2 2 2 2 2 2 1 1 1 1 1 2 2 2 1 2 1 2 2 2 2 2 2 2 2 1 1 2 2 2 2 2 2 1
Output signal: 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA 4-20mA + 1x Relais (NC) 4-20mA + 2x relay (NC) 0,5-4,5V 0,5-4,5V analogue 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V 0,5-4,5V
Output signal centre position/ zero position: 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 12mA 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V 2,5V
Output signal max.: 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA - - - - - - - - - - - - - - - - - -
Output signal max.: - - - - - - - - - - - - - - - - - - 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC
Output signal min.: 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA - - - - - - - - - - - - - - - - - -
Output signal min.: - - - - - - - - - - - - - - - - - - 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC
Polarity reversal protection: -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC
Repeating accuracy: ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 °
Resolution: < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° < 0,014 ° 0,01 °
Sensing rate: 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz
Short-circuit protection: ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2
Supply voltage: +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC
Switching points: - - - - - - - - - - - - - - - - - X1/X3 = 10<br>Y1/Y3 = 10 ° X1/X3 = 10°<br>Y1/Y3 = 10° ° - - - - - - - - - - - - - - - - - -
Technology: MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS
Temperature coefficient: max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K
Tolerance output signal: max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±200 µA max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV max. ±100 mV
Turn-off delay: - - - - - - - - - - - - - - - - - 1s - - - - - - - - - - - - - - - - - -
Turn-on delay: - - - - - - - - - - - - - - - - - 1s - - - - - - - - - - - - - - - - - -
Typical linearity error: 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range 1% of measuring range
Zero justification: ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60°
Mechanical data
Torque for fastening screws: 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm
Material information
Housing material: PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT
Environmental conditions
Operating temperature: -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40°C...+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C
Protection class: IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test: DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm): EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature: -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40°C...+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C
Vibration resistance (Norm): EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7.99g, 5 - 500Hz, 20.1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation: vertically horizontal horizontal horizontal horizontal horizontal horizontal horizontal vertically vertically vertically vertically vertically vertically vertically vertically vertically horizontal vertically horizontal horizontal horizontal horizontal horizontal horizontal horizontal horizontal vertically vertically vertically vertically vertically vertically vertically vertically vertically
Weight: 113 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 113 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g 108 g
Connection
Connector type: 1xM12 5-polig (male) 1xM12 Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA 1xM12 5-polig (male) 1xM12 Deutsch DT04-08PA Deutsch 8-polig Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA
Approvals
CE:
E1 type approval: UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00 UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI100V2-001
€450.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±45°<br>Y-axis: ±45°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±45° X-Achse<br>±45° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
113 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-001
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±5°<br>Y-axis: ±5°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±5° X-Achse<br>±5° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-002
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°<br>Y-axis: ±10°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse<br>±10° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-003
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±15°<br>Y-axis: ±15°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±15° X-Achse<br>±15° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-004
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±20°<br>Y-axis: ±20°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±20° X-Achse<br>±20° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-005
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±25°<br>Y-axis: ±25°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±25° X-Achse<br>±25° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-006
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±30°<br>Y-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° X-Achse<br>±30° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102H2-007
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±45°<br>Y-axis: ±45°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±45° X-Achse<br>±45° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V1-001
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±15°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±15° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V1-002
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±20°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±20° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V1-003
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V1-004
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±50°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±50° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V1-005
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±60°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±60° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V2-002
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±20°<br>Z-axis: ±20°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±20° X-Achse<br>±20° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V2-003
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±30°<br>Z-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° X-Achse<br>±30° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V2-004
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°<br>Z-axis: ±10°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse<br>±10° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI102V3-001
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
4-20mA
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAI1D2H2-001
€450.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±15°<br>Y-axis: ±15°
Connection type (switching output):
Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = -
Contact form:
NC
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
22mA
Hysteresis:
±0,1°
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
UB +8..+36 V DC 120-270 Ohm<br>UB +14..+36 V DC 120-500 Ohm
MTTF:
76 a
Max. switching current:
1 A
Max. switching power:
30 W
Max. switching voltage:
36 V DC
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±15° X-Achse<br>±15° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
4-20mA + 1x Relais (NC) 4-20mA + 2x relay (NC)
Output signal centre position/ zero position:
12mA
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
X1/X3 = 10<br>Y1/Y3 = 10 ° X1/X3 = 10°<br>Y1/Y3 = 10° °
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±200 µA
Turn-off delay:
1s
Turn-on delay:
1s
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU700V1-001
€450.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
113 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-001
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±5°<br>Y-axis: ±5°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982 Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 14
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1 Load dump Pulse B wiht Us = 85V, Cranking ISO 16750-2 Level 14
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±5° X-Achse<br>±5° Y-Achse
Measuring range acceleration max.:
±8 g 8 g
Measuring range gyroscope max.:
±250 °/s 250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V analogue
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 ° 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -40°C...+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C -40°C...+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7.99g, 5 - 500Hz, 20.1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA Deutsch 8-polig
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-002
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°<br>Y-axis: ±10°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse<br>±10° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-003
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±15°<br>Y-axis: ±15°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±15° X-Achse<br>±15° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-004
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±20°<br>Y-axis: ±20°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±20° X-Achse<br>±20° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-005
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±25°<br>Y-axis: ±25°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±25° X-Achse<br>±25° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-006
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±30°<br>Y-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° X-Achse<br>±30° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-007
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±60°<br>Y-axis: ±60°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±60° X-Achse<br>±60° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702H2-008
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°<br>Y-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse<br>±30° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V1-001
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±25°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±25° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V1-002
€420.00
Electrical data
Angle measuring range - analogue output:
Z-axis: ±60°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±60° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-001
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±10°<br>Z-axis: ±10°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±10° X-Achse<br>±10° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-002
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±20°<br>Z-axis: ±20°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±20° X-Achse<br>±20° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-003
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±25°<br>Z-axis: ±25°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±25° X-Achse<br>±25° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-004
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±30°<br>Z-axis: ±30°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±30° X-Achse<br>±30° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-005
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±40°<br>Z-axis: ±40°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±40° X-Achse<br>±40° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V2-006
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±45°<br>Z-axis: ±45°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±45° X-Achse<br>±45° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00
N6SAU702V3-001
€420.00
Electrical data
Angle measuring range - analogue output:
X-axis: ±120°
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Function error output signal:
5V
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
Limit frequency:
20Hz
Linearity error:
max. 1% vom Messbereich
Load resistance:
1-47 kOhm
MTTF:
76 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
(quasi-) static (non-moving applications / slow movements)
Measuring range:
±120° X-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Number of measurement axes (Number):
1
Number of measurement axes tilt:
1
Output signal:
0,5-4,5V
Output signal centre position/ zero position:
2,5V
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Polarity reversal protection:
-36 V DC
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
< 0,014 ° 0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Tolerance output signal:
max. ±100 mV
Turn-off delay:
-
Turn-on delay:
-
Typical linearity error:
1% of measuring range
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
Approvals
CE:
E1 type approval:
UN ECE Regulation No. 10 No. 10R06/01 9376 00