Angle sensor 120° CCW - 424A16A120 - 0.5-4.5Vra | elostore
Angle sensor 120° CCW - 424A16A120 - 0.5-4.5Vra
Angle sensor 120° CCW - 424A16A120 - 0.5-4.5Vra
  • Product details
  • Technical Data

Angle sensor 120° CCW - 424A16A120 - 0.5-4.5Vra

per item €118.29

available (10 pcs.), ships within 1-3 days

Quantity Price
from 5 pcs. €112.38 - 5 %
from 10 pcs. €103.95 - 12 %
from 25 pcs. €93.56 - 21 %
from 50 pcs. €84.20 - 29 %
from 100 pcs. €75.78 - 36 %

Choose variant:

Create offer

available (10 pcs.), ships within 1-3 days

Product information
Country of origin D
Item weight 0.065 kg
Customs tariff number 90318020
Attention: Please note that the operating lever is NOT included in the scope of delivery for all variants (see technical data)!

The 424A angle sensor is used to measure angles in the range between 30° and 120°. The 424A is based on the contactless Hall measuring principle, this is extremely reliable and ensures a long service life.

Due to the high IP67 protection class, the sensor can also be used in harsh environmental conditions. Because of their robustness, the sensors are particularly suitable for detecting the angular positions of rotational elements under extreme environmental conditions, such as on mobile machinery, in cranes, excavators, ships, mobile and stationary waste compactors, valve control, robotics and wind power plants or in large medical equipment.

Features
  • Long service life and reliability through contactless measuring principle with Hall sensor
  • Angular measurement range from 30° to 120°
  • IP67 protection class for harsh environmental conditions
  • High temperature resistance from -40 °C to +85 °C
  • Resolution 0.1°
  • Various current or voltage output signals
  • Infinitely short-​circuit proof
  • Available together with actuation lever for simple connection
  • EMV stabile for the motor vehicle sector, field withstand 200 V/m
  • Ball bearing (optionally with plain bearing)
Downloads "Angle sensor 120° CCW - 424A16A120 - 0.5-4.5Vra"
Technical Data
424A01A060
€127.75
424A01A090B
€133.08
424A06A030B
€127.75
424A07A045B
€137.10
424A07A090B
€137.10
424A07A120B
€137.10
424A10A030
€127.75
424A10A030B
€137.10
424A10A050
€127.75
424A10A060
€127.75
424A10A070
€127.75
424A10A090
€127.75
424A10A120
€127.75
424A10A120B
€137.10
424A11A030
€127.75
424A11A030B
€137.10
424A11A045
€127.75
424A11A050
€127.75
424A11A060
€127.75
424A11A070
€127.75
424A11A090
€127.75
424A11A100
€127.75
424A11A120
€127.75
424A11A120B
€137.10
424A16A060
€118.29
424A16A060B
€127.75
424A16A070
€118.29
424A16A090
€118.29
424A16A100
€118.29
424A16A120
€118.29
424A17A050
€127.75
424A17A070
€127.75
424A17A090
€127.75
424A17A090B
€137.10
424A17A100B
€137.10
424A17A120
€127.75
Electrical data
Angle measuring range: 60 ° 90 ° 30 ° 30°...120 ° 45 ° 90 ° 120 ° 30 ° 30 ° 50 ° 60 ° 70 ° 90 ° 120 ° 120 ° 30 ° 30 ° 45 ° 50 ° 60 ° 70 ° 90 ° 100 ° 120 ° 120 ° 60 ° 60 ° 60 ° 90 ° 100 ° 120 ° 50 ° 90 ° 90 ° 90 ° 100 ° 120 °
Current consumption: 18 mA 18 mA 10 mA 10 mA 10 mA 10 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA 8 mA 8 mA 8 mA 8 mA 8 mA 8 mA 10 mA 10 mA 10 mA 10 mA 10 mA 10 mA
EMC Agricultural and forestry machines (Norm): EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>conducted disturbance not applicable for 5V supply EN ISO 14982<br>conducted disturbance not applicable for 5V supply EN ISO 14982<br>conducted disturbance not applicable for 5V supply EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>conducted disturbance not applicable for 5V supply [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm): DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>pulse "load dump"; ´max. voltage 35V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm): DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895
Load resistance max.: 250 Ohm 250 Ohm - - - - - - - - - - - - 1250 Ohm 250 Ohm 250 Ohm 1250 Ohm 250 Ohm 250 Ohm 250 Ohm 1250 Ohm 250 Ohm 250 Ohm - - - - - - - - - - - -
Load resistance min.: - - 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 250 Ohm - - 250 Ohm - - - 250 Ohm - - 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm 20000 Ohm
MTTF: 101 a 101 a 133 a 133 a 133 a 133 a 101 a 133 a 133 a 101 a 133 a 101 a 101 a 133 a 101 a 101 a 101 a 101 a 101 a 101 a 101 a 101 a 101 a 101 a 225.7 a 225.7 a 225.7 a 225.7 a 225.7 a 225.7 a 133 a 133 a 133 a 225.7 a 133 a 133 a
Operating voltage max.: 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 5.5 V DC 5.5 V DC 5.5 V DC 5.5 V DC 5.5 V DC 5.5 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC
Operating voltage min.: 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC
Output signal - centre position/zero position: 12 mA 12 mA - - - - - - - - - - - - 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA - - - - - - - - - - 10 mA -
Output signal - centre position/zero position: - - 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 3 V DC 3 V DC 3 V DC 3 V DC 3 V DC 3 V DC 3 V DC 3 V DC - - - - - - - - - - 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC 2.5 V DC
Output signal max.: 20 mA 20 mA - - - - - - - - - - - - 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA - - - - - - - - - - - -
Output signal max.: - - 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 5 V DC 5 V DC 5 V DC 5 V DC 5 V DC 5 V DC 5 V DC 5 V DC - - - - - - - - - - 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC 4.5 V DC
Output signal min.: 4 mA 4 mA - - - - - - - - - - - - 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA - - - - - - - - - - - -
Output signal min.: - - 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 1 V DC 1 V DC 1 V DC 1 V DC 1 V DC 1 V DC 1 V DC 1 V DC - - - - - - - - - - 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC 0.5 V DC
Outputs: 4...20mA 4...20mA 0,5...4,5V 0,5...4,5V 0,5...4,5V 0,5...4,5V 1...5V 1...5V 1...5V 1...5V 1...5V 1...5V 1...5V 1...5V 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 0,5...4,5V ratiometric 0,5...4,5V ratiometric 0,5...4,5V ratiometric 0,5...4,5V ratiometric 0,5...4,5V ratiometric 0,5...4,5V ratiometric 0,5...4,5V 0,5...4,5V 0,5...4,5V 0,5...4,5V 0,5...4,5V 0,5...4,5V
Outputs (quantity, type): 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Polarity reversal protection:
Resolution: 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° - 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 °
Short-circuit resistance to GND: - - - - - - - - - - - - - - - - -
Short-circuit resistance to supply: - - - - - - - - - - - - - - - - -
Signal sequence: CCW CCW CCW Standard CCW (optional CW) CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW CCW
Signal update rate: 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz
Technology: Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall Hall
Temperature coefficient: typ. ±250 ppm/K typ. +-250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K 250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K 250 ppm/K 250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K 250 ppm/K typ. +- 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error: ±1,0° ±2,0° ±0,4° ±5,0° ±0,2° ±0,2° ±1,0°<br><br><br><br>° typ. ±2,0° ±5,0° ±2,0° typ. ±2,0° ±5,0°
Mechanical data
Actuating lever: Selectable YES Nein NO Nein NO Nein Nein YES Nein NO Nein NO NO NO Nein NO NO Nein NO Nein NO YES Ja
Bearing: Plain bearing Plain bearing Ball bearing Plain bearing Plain bearing Plain bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Plain bearing Ball bearing Ball bearing Ball bearing Ball bearing
Max. shaft load, axial: 50 N 0 N 50 N 0 N 50 N 50 N 0 N 50 N 0 N 50 N 0 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N 0 N 50 N 50 N 50 N 50 N
Max. shaft load, radial: 100 N 1 N 100 N 1 N 100 N 100 N 1 N 100 N 1 N 100 N 1 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N 1 N 100 N 100 N 100 N 100 N
Mechanical stop: Optional - -
Material information
Housing material: PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT PBT
Environmental conditions
Max. operating temperature: 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Max. storage temperature: 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Min. storage temperature: -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
Operating temperature min.: -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
Protection class: IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Installation
Torque for fastening screws: 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m
Connection
Connector type: AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5 AMP Superseal 1.5
424A01A060
€145.89
Electrical data
Angle measuring range:
60 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±1,0°
Mechanical data
Actuating lever:
Bearing:
Plain bearing
Max. shaft load, axial:
50 N 0 N
Max. shaft load, radial:
100 N 1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A01A090B
€156.57
Electrical data
Angle measuring range:
90 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Plain bearing
Max. shaft load, axial:
50 N 0 N
Max. shaft load, radial:
100 N 1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A06A030B
€145.89
Electrical data
Angle measuring range:
30 ° 30°...120 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW Standard CCW (optional CW)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Selectable
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Optional
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A07A045B
€156.57
Electrical data
Angle measuring range:
45 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±0,4°
Mechanical data
Actuating lever:
Bearing:
Plain bearing
Max. shaft load, axial:
50 N 0 N
Max. shaft load, radial:
100 N 1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A07A090B
€156.57
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Plain bearing
Max. shaft load, axial:
50 N 0 N
Max. shaft load, radial:
100 N 1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A07A120B
€156.57
Electrical data
Angle measuring range:
120 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Plain bearing
Max. shaft load, axial:
50 N 0 N
Max. shaft load, radial:
100 N 1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A030
€145.89
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
-
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A030B
€156.57
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±0,2°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A050
€145.89
Electrical data
Angle measuring range:
50 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A060
€145.89
Electrical data
Angle measuring range:
60 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
-
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
-
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A070
€145.89
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A090
€145.89
Electrical data
Angle measuring range:
90 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A120
€145.89
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A10A120B
€156.57
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
3 V DC
Output signal max.:
-
Output signal max.:
5 V DC
Output signal min.:
-
Output signal min.:
1 V DC
Outputs:
1...5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A030
€145.89
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A030B
€156.57
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±0,2°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A045
€145.89
Electrical data
Angle measuring range:
45 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A050
€145.89
Electrical data
Angle measuring range:
50 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A060
€145.89
Electrical data
Angle measuring range:
60 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A070
€145.89
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A090
€145.89
Electrical data
Angle measuring range:
90 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A100
€145.89
Electrical data
Angle measuring range:
100 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A120
€145.89
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A11A120B
€156.57
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
101 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A060
€135.09
Electrical data
Angle measuring range:
60 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A060B
€145.89
Electrical data
Angle measuring range:
60 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>conducted disturbance not applicable for 5V supply
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±1,0°<br><br><br><br>°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A070
€135.09
Electrical data
Angle measuring range:
60 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>conducted disturbance not applicable for 5V supply
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A090
€135.09
Electrical data
Angle measuring range:
90 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>conducted disturbance not applicable for 5V supply
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
typ. ±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A100
€135.09
Electrical data
Angle measuring range:
100 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>conducted disturbance not applicable for 5V supply
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) DIN EN ISO 13766-1<br>conducted disturbance not applicable for 5V supply
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A16A120
€135.09
Electrical data
Angle measuring range:
120 °
Current consumption:
8 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
5.5 V DC
Operating voltage min.:
4.5 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V ratiometric
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Nein
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A050
€145.89
Electrical data
Angle measuring range:
50 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. +- 250 ppm/K typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A070
€145.89
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Plain bearing
Max. shaft load, axial:
0 N
Max. shaft load, radial:
1 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A090
€145.89
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A090B
€156.57
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump"; ´max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
225.7 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
typ. ±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A100B
€156.57
Electrical data
Angle measuring range:
100 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
10 mA
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
Short-circuit resistance to supply:
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
Ja
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5
424A17A120
€145.89
Electrical data
Angle measuring range:
120 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
133 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.1 °
Short-circuit resistance to GND:
-
Short-circuit resistance to supply:
-
Signal sequence:
CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K typ. +-250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Superseal 1.5