Product information
Country of origin | D |
---|---|
Item weight | 0.071 kg |
Customs tariff number | 85365019 |
They can be attached to or integrated in all kinds of protective equipment. The variety of designs and the applied technology with complete mechanical compatibility make them especially valuable for users.
The used RFID technology enables the eloProtect E sensors to be coded individually and in a scalable way. Therefore the tampering protection can be selected according to the application. At the highest coding level, the sensor accepts only one corresponding actuator. The use of this reliable technology simplifies the mounting conditions through higher misalignment tolerance and enables the installation of series connections up to PL e / SIL3. As a result, nothing stands in the way of simple integration of eloProtect E sensors in an existing safety concept. These safety sensors also offer a flexible and cost-effective solution for modifying machines.
Features
-
Extremely high protection against tampering due to individual coding
-
Versions with cable outlet or pigtail connector
-
Simple diagnostics through control output and LED display on the sensor
-
Integrated evaluation with EDM/start input and OSSD outputs enables operation as a stand-alone unit
-
Contactors up to 400mA current consumption can be connected directly to the OSSD outputs
-
Series connection of up to 30 units possible
-
Simple wiring due to pluggable T-pieces
Downloads "RFID safety sensor eloProtect E - 153ESK00K11 - 8-pin, coded, auto, 1m cable"
Technical Data
153ESK00J11
€253.38
|
153ESK00J21
€409.89
|
153ESK00J31
€327.87
|
153ESK00K11
€196.74
|
||
Electrical data
|
|||||
Active surface (Number): | 1 | 1 | 1 | 1 | |
---|---|---|---|---|---|
Actuation: | arbitrary | arbitrary | arbitrary | arbitrary | |
Assured switch-off distance (Sar): | 18 mm | 18 mm | 18 mm | 18 mm | |
Assured switching distance (Sao): | 8 mm | 8 mm | 8 mm | 8 mm | |
Coding variant: | coded | unikat | individually coded | coded | |
Contact form: | OSSD | OSSD | OSSD | OSSD | |
Cross-short detection: | |||||
Current consumption per input: | 2.75 mA | 2.75 mA | 2.75 mA | 2.75 mA | |
EDM/start input: | |||||
Fuse operating voltage: | 1A fast | 1A fast | 1A fast | 1A fast | |
Hysteresis: | 2 mm | 2 mm | 2 mm | 2 mm | |
Internal electronic fuse: | |||||
LED display: | three-coloured | three-coloured | three-coloured | three-coloured | |
Max. switching current at control output: | 0.05 A | 0.05 A | 0.05 A | 0.05 A | |
Max. switching current at safety output: | 0.4 A | 0.4 A | 0.4 A | 0.4 A | |
Minimum switching distance (S0 min): | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | |
No-load current I0: | 30 mA | 30 mA | 30 mA | 30 mA | |
Number of electronic control outputs: | 1 | 1 | 1 | 1 | |
Number of electronic safety outputs: | 2 | 2 | 2 | 2 | |
Number of safety inputs: | 2 | 2 | 2 | 2 | |
Overvoltage category: | II | II | II | II | |
Polarity reversal protection: | |||||
Pollution degree: | 2 | 2 | 2 | 2 | |
Power consumption: | 24 W | 24 W | 24 W | 24 W | |
Rated impulse withstand voltage (Uimp): | 1000 V | 1000 V | 1000 V | 1000 V | |
Rated insulation voltage (Ui): | 50 V | 50 V | 50 V | 50 V | |
Rated operating voltage (Ue): | 24 V | 24 V | 24 V | 24 V | |
Rated switching distance (Sn): | 12 mm | 12 mm | 12 mm | 12 mm | |
Readiness delay (tv): | 1000 ms | 1000 ms | 1000 ms | 1000 ms | |
Repeating accuracy: | < 0,5 mm | < 0,5 mm | < 0,5 mm | < 0,5 mm | |
Short-circuit detection: | |||||
Stabilised PELV/SELV power supply: | required | required | required | required | |
Start function: | automatic | automatic | automatic | automatic | |
Switching frequency: | 3 Hz | 3 Hz | 3 Hz | 3 Hz | |
Switching principle: | electronic | electronic | electronic | electronic | |
Technology: | RFID | RFID | RFID | RFID | |
Turn-on delay (ton): | 75 ms | 75 ms | 75 ms | 75 ms | |
Utilization category: | AC-12 / DC-13 | AC-12 / DC-13 | AC-12 / DC-13 | AC-12 / DC-13 | |
Voltage drop (Ud): | 0.75 V | 0.75 V | 0.75 V | 0.75 V | |
wurde angepasst (Number): | 30 | 30 | 30 | 30 | |
Safety-related characteristics
|
|||||
Category acc. to EN ISO 13849-1: | 4 | 4 | 4 | 4 | |
Coding acc. to EN ISO 14119: | Low | High | High | Low | |
Hardware fault tolerance (HFT) according to IEC 61508: | 1 | 1 | 1 | 1 | |
Mission time in years: | 20 a | 20 a | 20 a | 20 a | |
PFHD according to IEC 61508: | 2,24x10^-9 1/h | 2,24x10^-9 1/h | 2,24x10^-9 1/h | 2,24x10^-9 1/h | |
PL acc. to EN ISO 13849-1: | e | e | e | e | |
SIL CL acc. to IEC 62061: | 3 | 3 | 3 | 3 | |
SIL acc. to IEC 61508: | 3 | 3 | 3 | 3 | |
Structure acc. to EN ISO 13849-1: | Two-channel | Two-channel | Two-channel | Two-channel | |
Type acc. to EN ISO 14119: | 4 | 4 | 4 | 4 | |
Mechanical data
|
|||||
Actuation frequency: | 180 1/h | 180 1/h | 180 1/h | 180 1/h | |
Dimensions: | 26 x 36 x 13 mm | 26 x 36 x 13 mm | 26 x 36 x 13 mm | 26 x 36 x 13 mm | |
Free zone: | 50 mm | 50 mm | 50 mm | 50 mm | |
Housing design: | rectangular | rectangular | rectangular | rectangular | |
Minimum installation distance (between two sensors): | 150 mm | 150 mm | 150 mm | 150 mm | |
cannot be mounted flush: | |||||
Material information
|
|||||
Cable material: | PVC | PVC | PVC | PVC | |
Housing colour: | grau, schwarz | grau, schwarz | grau, schwarz | grau, schwarz | |
Housing material: | PBT, PC | PBT, PC | PBT, PC | PBT, PC | |
Environmental conditions
|
|||||
Air pressure: | 860 - 1060 hPa | 860 - 1060 hPa | 860 - 1060 hPa | 860 - 1060 hPa | |
Continuous shock resistance (Norm): | 10 g / 16 ms | 10 g / 16 ms | 10 g / 16 ms | 10 g / 16 ms | |
Delta tmax: | 0.5 °C/min | 0.5 °C/min | 0.5 °C/min | 0.5 °C/min | |
Max. cable temperature range, fixed installation: | 80 °C | 80 °C | 80 °C | 80 °C | |
Max. cable temperature range, moving: | 80 °C | 80 °C | 80 °C | 80 °C | |
Max. operating temperature: | 70 °C | 70 °C | 70 °C | 70 °C | |
Max. storage temperature: | 70 °C | 70 °C | 70 °C | 70 °C | |
Min. cable temperature range, fixed installation: | -30 °C | -30 °C | -30 °C | -30 °C | |
Min. cable temperature range, moving: | -5 °C | -5 °C | -5 °C | -5 °C | |
Min. storage temperature: | -25 °C | -25 °C | -25 °C | -25 °C | |
Operating temperature min.: | -25 °C | -25 °C | -25 °C | -25 °C | |
Protection class, connector: | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | - | |
Protection class, housing: | IP67 DIN EN 60529 - IP6K9K ISO 20653 | IP67 DIN EN 60529 - IP6K9K ISO 20653 | IP67 DIN EN 60529 - IP6K9K ISO 20653 | IP67 DIN EN 60529 - IP6K9K ISO 20653 | |
Relative humidity: | 5 - 85 % | 5 - 85 % | 5 - 85 % | 5 - 85 % | |
Shock resistance (Norm): | 30 g / 11 ms | 30 g / 11 ms | 30 g / 11 ms | 30 g / 11 ms | |
Vibration resistance (Norm): | 10 ... 55 Hz | 10 ... 55 Hz | 10...55 Hz | 10 ... 55 Hz | |
Installation
|
|||||
Mounting type: | screwed | screwed | screwed | screwed | |
Torque for fastening screws: | 0.7 N m | 0.7 N m | 0.7 N m | 0.7 N m | |
Weight: | 45 g | 45 g | 45 g | 70 g | |
Connection
|
|||||
Cable colour: | grau | grau | grau | grau | |
Cable length: | 0.15 m | 0.15 m | 0.15 m | 1 m | |
Cable type: | LiYY | LiYY | LiYY | LiYY | |
Connector type: | M12x1 - 8 polig | M12x1 - 8 polig | M12x1 - 8 polig | - | |
Number of strands: | 8 | 8 | 8 | 8 | |
Wire cross section: | 0.25 mm^2 | 0.25 mm^2 | 0.25 mm^2 | 0.25 mm^2 | |
Approvals
|
|||||
CE label: | |||||
Certified in accordance with: | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.5 | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.9 | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.13 | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.4 | |
Operating data
|
|||||
Possible actuators: | 153EBK001 | 153EBK001 | 153EBK001 | 153EBK001 |
153ESK00J11
€253.38
Electrical data
Active surface (Number):
1
Actuation:
arbitrary
Assured switch-off distance (Sar):
18 mm
Assured switching distance (Sao):
8 mm
Coding variant:
coded
Contact form:
OSSD
Cross-short detection:
Current consumption per input:
2.75 mA
EDM/start input:
Fuse operating voltage:
1A fast
Hysteresis:
2 mm
Internal electronic fuse:
LED display:
three-coloured
Max. switching current at control output:
0.05 A
Max. switching current at safety output:
0.4 A
Minimum switching distance (S0 min):
0.5 mm
No-load current I0:
30 mA
Number of electronic control outputs:
1
Number of electronic safety outputs:
2
Number of safety inputs:
2
Overvoltage category:
II
Polarity reversal protection:
Pollution degree:
2
Power consumption:
24 W
Rated impulse withstand voltage (Uimp):
1000 V
Rated insulation voltage (Ui):
50 V
Rated operating voltage (Ue):
24 V
Rated switching distance (Sn):
12 mm
Readiness delay (tv):
1000 ms
Repeating accuracy:
< 0,5 mm
Short-circuit detection:
Stabilised PELV/SELV power supply:
required
Start function:
automatic
Switching frequency:
3 Hz
Switching principle:
electronic
Technology:
RFID
Turn-on delay (ton):
75 ms
Utilization category:
AC-12 / DC-13
Voltage drop (Ud):
0.75 V
wurde angepasst (Number):
30
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
Low
Hardware fault tolerance (HFT) according to IEC 61508:
1
Mission time in years:
20 a
PFHD according to IEC 61508:
2,24x10^-9 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
180 1/h
Dimensions:
26 x 36 x 13 mm
Free zone:
50 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
150 mm
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
grau, schwarz
Housing material:
PBT, PC
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
80 °C
Max. cable temperature range, moving:
80 °C
Max. operating temperature:
70 °C
Max. storage temperature:
70 °C
Min. cable temperature range, fixed installation:
-30 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class, connector:
IP67 DIN EN 60529
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Torque for fastening screws:
0.7 N m
Weight:
45 g
Connection
Cable colour:
grau
Cable length:
0.15 m
Cable type:
LiYY
Connector type:
M12x1 - 8 polig
Number of strands:
8
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.5
Operating data
Possible actuators:
153EBK001
153ESK00J21
€409.89
Electrical data
Active surface (Number):
1
Actuation:
arbitrary
Assured switch-off distance (Sar):
18 mm
Assured switching distance (Sao):
8 mm
Coding variant:
unikat
Contact form:
OSSD
Cross-short detection:
Current consumption per input:
2.75 mA
EDM/start input:
Fuse operating voltage:
1A fast
Hysteresis:
2 mm
Internal electronic fuse:
LED display:
three-coloured
Max. switching current at control output:
0.05 A
Max. switching current at safety output:
0.4 A
Minimum switching distance (S0 min):
0.5 mm
No-load current I0:
30 mA
Number of electronic control outputs:
1
Number of electronic safety outputs:
2
Number of safety inputs:
2
Overvoltage category:
II
Polarity reversal protection:
Pollution degree:
2
Power consumption:
24 W
Rated impulse withstand voltage (Uimp):
1000 V
Rated insulation voltage (Ui):
50 V
Rated operating voltage (Ue):
24 V
Rated switching distance (Sn):
12 mm
Readiness delay (tv):
1000 ms
Repeating accuracy:
< 0,5 mm
Short-circuit detection:
Stabilised PELV/SELV power supply:
required
Start function:
automatic
Switching frequency:
3 Hz
Switching principle:
electronic
Technology:
RFID
Turn-on delay (ton):
75 ms
Utilization category:
AC-12 / DC-13
Voltage drop (Ud):
0.75 V
wurde angepasst (Number):
30
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
High
Hardware fault tolerance (HFT) according to IEC 61508:
1
Mission time in years:
20 a
PFHD according to IEC 61508:
2,24x10^-9 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
180 1/h
Dimensions:
26 x 36 x 13 mm
Free zone:
50 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
150 mm
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
grau, schwarz
Housing material:
PBT, PC
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
80 °C
Max. cable temperature range, moving:
80 °C
Max. operating temperature:
70 °C
Max. storage temperature:
70 °C
Min. cable temperature range, fixed installation:
-30 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class, connector:
IP67 DIN EN 60529
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Torque for fastening screws:
0.7 N m
Weight:
45 g
Connection
Cable colour:
grau
Cable length:
0.15 m
Cable type:
LiYY
Connector type:
M12x1 - 8 polig
Number of strands:
8
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.9
Operating data
Possible actuators:
153EBK001
153ESK00J31
€327.87
Electrical data
Active surface (Number):
1
Actuation:
arbitrary
Assured switch-off distance (Sar):
18 mm
Assured switching distance (Sao):
8 mm
Coding variant:
individually coded
Contact form:
OSSD
Cross-short detection:
Current consumption per input:
2.75 mA
EDM/start input:
Fuse operating voltage:
1A fast
Hysteresis:
2 mm
Internal electronic fuse:
LED display:
three-coloured
Max. switching current at control output:
0.05 A
Max. switching current at safety output:
0.4 A
Minimum switching distance (S0 min):
0.5 mm
No-load current I0:
30 mA
Number of electronic control outputs:
1
Number of electronic safety outputs:
2
Number of safety inputs:
2
Overvoltage category:
II
Polarity reversal protection:
Pollution degree:
2
Power consumption:
24 W
Rated impulse withstand voltage (Uimp):
1000 V
Rated insulation voltage (Ui):
50 V
Rated operating voltage (Ue):
24 V
Rated switching distance (Sn):
12 mm
Readiness delay (tv):
1000 ms
Repeating accuracy:
< 0,5 mm
Short-circuit detection:
Stabilised PELV/SELV power supply:
required
Start function:
automatic
Switching frequency:
3 Hz
Switching principle:
electronic
Technology:
RFID
Turn-on delay (ton):
75 ms
Utilization category:
AC-12 / DC-13
Voltage drop (Ud):
0.75 V
wurde angepasst (Number):
30
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
High
Hardware fault tolerance (HFT) according to IEC 61508:
1
Mission time in years:
20 a
PFHD according to IEC 61508:
2,24x10^-9 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
180 1/h
Dimensions:
26 x 36 x 13 mm
Free zone:
50 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
150 mm
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
grau, schwarz
Housing material:
PBT, PC
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
80 °C
Max. cable temperature range, moving:
80 °C
Max. operating temperature:
70 °C
Max. storage temperature:
70 °C
Min. cable temperature range, fixed installation:
-30 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class, connector:
IP67 DIN EN 60529
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10...55 Hz
Installation
Mounting type:
screwed
Torque for fastening screws:
0.7 N m
Weight:
45 g
Connection
Cable colour:
grau
Cable length:
0.15 m
Cable type:
LiYY
Connector type:
M12x1 - 8 polig
Number of strands:
8
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.13
Operating data
Possible actuators:
153EBK001
153ESK00K11
€196.74
Electrical data
Active surface (Number):
1
Actuation:
arbitrary
Assured switch-off distance (Sar):
18 mm
Assured switching distance (Sao):
8 mm
Coding variant:
coded
Contact form:
OSSD
Cross-short detection:
Current consumption per input:
2.75 mA
EDM/start input:
Fuse operating voltage:
1A fast
Hysteresis:
2 mm
Internal electronic fuse:
LED display:
three-coloured
Max. switching current at control output:
0.05 A
Max. switching current at safety output:
0.4 A
Minimum switching distance (S0 min):
0.5 mm
No-load current I0:
30 mA
Number of electronic control outputs:
1
Number of electronic safety outputs:
2
Number of safety inputs:
2
Overvoltage category:
II
Polarity reversal protection:
Pollution degree:
2
Power consumption:
24 W
Rated impulse withstand voltage (Uimp):
1000 V
Rated insulation voltage (Ui):
50 V
Rated operating voltage (Ue):
24 V
Rated switching distance (Sn):
12 mm
Readiness delay (tv):
1000 ms
Repeating accuracy:
< 0,5 mm
Short-circuit detection:
Stabilised PELV/SELV power supply:
required
Start function:
automatic
Switching frequency:
3 Hz
Switching principle:
electronic
Technology:
RFID
Turn-on delay (ton):
75 ms
Utilization category:
AC-12 / DC-13
Voltage drop (Ud):
0.75 V
wurde angepasst (Number):
30
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
Low
Hardware fault tolerance (HFT) according to IEC 61508:
1
Mission time in years:
20 a
PFHD according to IEC 61508:
2,24x10^-9 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
180 1/h
Dimensions:
26 x 36 x 13 mm
Free zone:
50 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
150 mm
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
grau, schwarz
Housing material:
PBT, PC
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
80 °C
Max. cable temperature range, moving:
80 °C
Max. operating temperature:
70 °C
Max. storage temperature:
70 °C
Min. cable temperature range, fixed installation:
-30 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class, connector:
-
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Torque for fastening screws:
0.7 N m
Weight:
70 g
Connection
Cable colour:
grau
Cable length:
1 m
Cable type:
LiYY
Connector type:
-
Number of strands:
8
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.4
Operating data
Possible actuators:
153EBK001
Documents and Downloads
Data sheets