RFID safety sensor eloProtect E - 153ESK00K11-5 - 8-pin, coded, auto, 5m cable
per item €216.12
available (9 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 10 pcs. | €194.51 - 10 % |
from 25 pcs. | €172.90 - 20 % |
from 50 pcs. | €151.28 - 30 % |
Product number: 153ESK00K11-5
Product information
Country of origin | D |
---|---|
Item weight | 0.3 kg |
Customs tariff number | 85365019 |
They can be attached to or integrated in all kinds of protective equipment. The variety of designs and the applied technology with complete mechanical compatibility make them especially valuable for users.
The used RFID technology enables the eloProtect E sensors to be coded individually and in a scalable way. Therefore the tampering protection can be selected according to the application. At the highest coding level, the sensor accepts only one corresponding actuator. The use of this reliable technology simplifies the mounting conditions through higher misalignment tolerance and enables the installation of series connections up to PL e / SIL3. As a result, nothing stands in the way of simple integration of eloProtect E sensors in an existing safety concept. These safety sensors also offer a flexible and cost-effective solution for modifying machines.
Features
-
Extremely high protection against tampering due to individual coding
-
Versions with cable outlet or pigtail connector
-
Simple diagnostics through control output and LED display on the sensor
-
Integrated evaluation with EDM/start input and OSSD outputs enables operation as a stand-alone unit
-
Contactors up to 400mA current consumption can be connected directly to the OSSD outputs
-
Series connection of up to 30 units possible
-
Simple wiring due to pluggable T-pieces
Downloads "RFID safety sensor eloProtect E - 153ESK00K11-5 - 8-pin, coded, auto, 5m cable"
Technical Data
153ESK00K11-5
€216.12
|
||
Electrical data
|
||
Assured switching distance (Sao): | 8 mm | |
---|---|---|
Number of electronic safety outputs: | 2 | |
Pollution degree: | 2 | |
Rated switching distance (Sn): | 12 mm | |
LED display: | three-coloured | |
wurde angepasst (Number): | 30 | |
Rated operating voltage (Ue): | 24 V | |
Utilization category: | AC-12 / DC-13 | |
Fuse operating voltage: | 1A fast | |
Power consumption: | 24 W | |
Start function: | automatic | |
Current consumption per input: | 2.75 mA | |
Overvoltage category: | II | |
Voltage drop (Ud): | 0.75 V | |
No-load current I0: | 30 mA | |
Coding variant: | coded | |
Max. switching current at control output: | 0.05 A | |
Number of electronic control outputs: | 1 | |
Max. switching current at safety output: | 0.4 A | |
Switching frequency: | 3 Hz | |
Repeating accuracy: | < 0,5 mm | |
Switching principle: | electronic | |
Rated insulation voltage (Ui): | 50 V | |
Actuation: | arbitrary | |
Contact form: | OSSD | |
Cross-short detection: | ||
Polarity reversal protection: | ||
Hysteresis: | 2 mm | |
EDM/start input: | ||
Number of safety inputs: | 2 | |
Active surface (Number): | 1 | |
Short-circuit detection: | ||
Assured switch-off distance (Sar): | 18 mm | |
Technology: | RFID | |
Readiness delay (tv): | 1000 ms | |
Minimum switching distance (S0 min): | 0.5 mm | |
Stabilised PELV/SELV power supply: | required | |
Rated impulse withstand voltage (Uimp): | 1000 V | |
Turn-on delay (ton): | 75 ms | |
Internal electronic fuse: | ||
Safety-related characteristics
|
||
Category acc. to EN ISO 13849-1: | 4 | |
PL acc. to EN ISO 13849-1: | e | |
SIL acc. to IEC 61508: | 3 | |
PFHD according to IEC 61508: | 2,24x10^-9 1/h | |
Mission time in years: | 20 a | |
Structure acc. to EN ISO 13849-1: | Two-channel | |
SIL CL acc. to IEC 62061: | 3 | |
Hardware fault tolerance (HFT) according to IEC 61508: | 1 | |
Type acc. to EN ISO 14119: | 4 | |
Coding acc. to EN ISO 14119: | Low | |
Mechanical data
|
||
Free zone: | 50 mm | |
cannot be mounted flush: | ||
Housing design: | rectangular | |
Dimensions: | 26 x 36 x 13 mm | |
Actuation frequency: | 180 1/h | |
Minimum installation distance (between two sensors): | 150 mm | |
Material information
|
||
Housing colour: | grau, schwarz | |
Cable material: | PVC | |
Housing material: | PBT, PC | |
Environmental conditions
|
||
Max. cable temperature range, moving: | 80 °C | |
Max. cable temperature range, fixed installation: | 80 °C | |
Max. operating temperature: | 70 °C | |
Min. cable temperature range, moving: | -5 °C | |
Min. storage temperature: | -25 °C | |
Continuous shock resistance (Norm): | 10 g / 16 ms | |
Operating temperature min.: | -25 °C | |
Shock resistance (Norm): | 30 g / 11 ms | |
Min. cable temperature range, fixed installation: | -30 °C | |
Air pressure: | 860 - 1060 hPa | |
Max. storage temperature: | 70 °C | |
Delta tmax: | 0.5 °C/min | |
Relative humidity: | 5 - 85 % | |
Protection class, housing: | IP67 DIN EN 60529 - IP6K9K ISO 20653 | |
Vibration resistance (Norm): | 10 ... 55 Hz | |
Installation
|
||
Weight: | 70 g | |
Torque for fastening screws: | 0.7 N m | |
Mounting type: | screwed | |
Connection
|
||
Cable length: | 1 m | |
Wire cross section: | 0.25 mm^2 | |
Cable type: | LiYY | |
Number of strands: | 8 | |
Cable colour: | grau | |
Approvals
|
||
CE label: | ||
Certified in accordance with: | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.4 | |
Operating data
|
||
Possible actuators: | 153EBK001 |
153ESK00K11-5
€216.12
Electrical data
Assured switching distance (Sao):
8 mm
Number of electronic safety outputs:
2
Pollution degree:
2
Rated switching distance (Sn):
12 mm
LED display:
three-coloured
wurde angepasst (Number):
30
Rated operating voltage (Ue):
24 V
Utilization category:
AC-12 / DC-13
Fuse operating voltage:
1A fast
Power consumption:
24 W
Start function:
automatic
Current consumption per input:
2.75 mA
Overvoltage category:
II
Voltage drop (Ud):
0.75 V
No-load current I0:
30 mA
Coding variant:
coded
Max. switching current at control output:
0.05 A
Number of electronic control outputs:
1
Max. switching current at safety output:
0.4 A
Switching frequency:
3 Hz
Repeating accuracy:
< 0,5 mm
Switching principle:
electronic
Rated insulation voltage (Ui):
50 V
Actuation:
arbitrary
Contact form:
OSSD
Cross-short detection:
Polarity reversal protection:
Hysteresis:
2 mm
EDM/start input:
Number of safety inputs:
2
Active surface (Number):
1
Short-circuit detection:
Assured switch-off distance (Sar):
18 mm
Technology:
RFID
Readiness delay (tv):
1000 ms
Minimum switching distance (S0 min):
0.5 mm
Stabilised PELV/SELV power supply:
required
Rated impulse withstand voltage (Uimp):
1000 V
Turn-on delay (ton):
75 ms
Internal electronic fuse:
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
PL acc. to EN ISO 13849-1:
e
SIL acc. to IEC 61508:
3
PFHD according to IEC 61508:
2,24x10^-9 1/h
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
SIL CL acc. to IEC 62061:
3
Hardware fault tolerance (HFT) according to IEC 61508:
1
Type acc. to EN ISO 14119:
4
Coding acc. to EN ISO 14119:
Low
Mechanical data
Free zone:
50 mm
cannot be mounted flush:
Housing design:
rectangular
Dimensions:
26 x 36 x 13 mm
Actuation frequency:
180 1/h
Minimum installation distance (between two sensors):
150 mm
Material information
Housing colour:
grau, schwarz
Cable material:
PVC
Housing material:
PBT, PC
Environmental conditions
Max. cable temperature range, moving:
80 °C
Max. cable temperature range, fixed installation:
80 °C
Max. operating temperature:
70 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Continuous shock resistance (Norm):
10 g / 16 ms
Operating temperature min.:
-25 °C
Shock resistance (Norm):
30 g / 11 ms
Min. cable temperature range, fixed installation:
-30 °C
Air pressure:
860 - 1060 hPa
Max. storage temperature:
70 °C
Delta tmax:
0.5 °C/min
Relative humidity:
5 - 85 %
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Weight:
70 g
Torque for fastening screws:
0.7 N m
Mounting type:
screwed
Connection
Cable length:
1 m
Wire cross section:
0.25 mm^2
Cable type:
LiYY
Number of strands:
8
Cable colour:
grau
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.4
Operating data
Possible actuators:
153EBK001
Documents and Downloads
Data sheets