Safety sensor ATEX - 671V62NU0-5 - N.O./N.O., 5m cable
per item €454.53
available (1 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 25 pcs. | €409.08 - 10 % |
from 50 pcs. | €363.62 - 20 % |
from 100 pcs. | €318.17 - 30 % |
Ex-Marking: Nach RL 2014/34/EU ExII 2G Ex mb IIC T6/T5 Gb ExII 2D Ex mb IIIC IP68 T105°C Db
Choose variant:
Country of origin | D |
---|---|
Item weight | 0.6182 kg |
Customs tariff number | 85365019 |
Technical Data
671271I40-5
€492.96
|
671271IU012-5
€450.24
|
671271K40-10
€555.36
|
671271KU012-5
€471.57
|
671271MU0-10
€474.42
|
671271MU0-5
€433.32
|
671271NU0-10
€495.72
|
671271NU0-5
€454.53
|
671V62I40-5
€492.93
|
671V62K40-10
€555.39
|
671V62KU012-10
€512.70
|
671V62MU0-10
€474.42
|
671V62N40-10
€538.26
|
671V62NU0-10
€495.72
|
671V62NU0-5
€454.53
|
||
|
||||||||||||||||
Version dust: | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 1D Ex ia IIIC IP68 T 200 105°C Da | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | EX II 2D Ex mb IIIC IP68 T105°C Db | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical data
|
||||||||||||||||
Actuation: | front | front | front | front | front | front | front | front | front | front | front | front | front | front | front | |
Contact form: | NO/NC | NO/NC | NO/NC | NO/NO | NO/NC | NO/NC | NO/NC | NO/NC | NO/NO | NO/NO | NO/NC | NO/NO | NO/NO | NO/NO | NO/NO | |
Effective internal capacitance (Ci): | 2 nF | 2 nF | 2 nF | 2 nF | - | - | - | - | 2 nF | 2 nF | 2 nF | - | - | - | - | |
Effective internal inductance (Li): | 10 µH | 10 µH | 10 µH | 10 µH | - | - | - | - | 10 µH | 10 µH | 10 µH | - | - | - | - | |
Max. input voltage Ui (i): | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | 0 V AC/DC | - | - | - | - | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | - | - | - | - | |
Pollution degree: | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Rated voltage Un (mb): | - | - | - | - | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | - | - | - | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | 24 V AC/DC | |
Series resistor: | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | |
Switching frequency: | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | 5 Hz | |
Switching principle: | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | magnetic | |
Technology: | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | Reed | |
Safety-related characteristics
|
||||||||||||||||
Assured switch-off distance (Sar) with actuator (amplified): | 23 mm | 23 mm | 23 mm | 20 mm | 23 mm | 23 mm | 23 mm | 23 mm | 20 mm | 20 mm | 23 mm | 20 mm | 20 mm | 20 mm | 20 mm | |
Assured switch-off distance (Sar) with actuator (standard): | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm | |
Assured switching distance (Sao) with actuator (amplified): | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | 7 mm | |
Assured switching distance (Sao) with actuator (standard): | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | 4 mm | |
B10d acc. to EN ISO 13849-1: | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | 4000000 | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | |
Coding acc. to EN ISO 14119: | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | Low | |
Minimum switching distance (So min) with actuator (amplified): | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | 3 mm | |
Minimum switching distance (So min) with actuator (standard): | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | |
Mission time in years: | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | 20 a | |
Structure acc. to EN ISO 13849-1: | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | |
Type acc. to EN ISO 14119: | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
Mechanical data
|
||||||||||||||||
Detent present: | ||||||||||||||||
Dimensions: | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | M30 x 53 mm | |
Earth terminal: | ||||||||||||||||
Housing design: | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | cylindrical | |
Minimum installation distance (between two sensors): | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm | |
Material information
|
||||||||||||||||
Cable material: | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | PVC | |
Housing colour: | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | silber | |
Housing material: | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | |
Nut material: | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | Edelstahl | |
Environmental conditions
|
||||||||||||||||
Ambient temperature range Ta, (Ii total: 0 ... 60 mA): | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | - | - | - | - | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | - | - | - | - | |
Ambient temperature range Ta, (Ii total: 60 ... 150 mA): | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | - | - | - | - | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | T6: -25°C..+50° T5:T105°C: -25°C..+70°C | - | - | - | - | |
Ambient temperature range Ta, (In total: 0 ... 60 mA): | - | - | - | - | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | - | - | - | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | T6: -25°C..+70°C T5:T105°C: -25°C..+75°C | |
Ambient temperature range Ta, (In total: 60 ... 150 mA): | - | - | - | - | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | - | - | - | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | T6: -25°C..+50°C T5:T105°C: -25°C..+70°C | |
Max. storage temperature: | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | |
Min. storage temperature: | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | |
Protection class: | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | IP68 10bar | |
Shock resistance (Norm): | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | |
Vibration resistance (Norm): | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | 10 ... 55 Hz | |
Installation
|
||||||||||||||||
Mounting type: | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | Fastening nut | |
Thread: | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | M30 | |
Connection
|
||||||||||||||||
Cable colour: | grau | schwarz | grau | schwarz | schwarz | schwarz | schwarz | schwarz | grau | grau | schwarz | schwarz | grau | schwarz | schwarz | |
Cable length: | 5 m | 5 m | 10 m | 5 m | 10 m | 5 m | 10 m | 5 m | 5 m | 10 m | 10 m | 10 m | 10 m | 10 m | 5 m | |
Cable type: | LIYCYW | Y - UL 2517 | LIYCYW | Y - UL 2517 | Y - UL 2517 | Y - UL 2517 | Y - UL 2517 | Y - UL 2517 | LIYCYW | LIYCYW | Y - UL 2517 | Y - UL 2517 | LIYCYW | Y - UL 2517 | Y - UL 2517 |
671271I40-5
€492.96
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
5 m
Cable type:
LIYCYW
671271IU012-5
€450.24
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271K40-10
€555.36
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671271KU012-5
€471.57
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
0 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271MU0-10
€474.42
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671271MU0-5
€433.32
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271NU0-10
€495.72
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671271NU0-5
€454.53
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671V62I40-5
€492.93
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
4000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
5 m
Cable type:
LIYCYW
671V62K40-10
€555.39
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671V62KU012-10
€512.70
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62MU0-10
€474.42
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62N40-10
€538.26
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671V62NU0-10
€495.72
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62NU0-5
€454.53
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517