Angle sensor 359° CCW - 424D17359B - with operating lever - 0.5-4.5V
Part number:
Art. -No.
424D17359B
per item €186.52
available (25 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 5 pcs. | €177.19 - 5 % |
from 10 pcs. | €163.90 - 12 % |
from 25 pcs. | €147.51 - 21 % |
from 50 pcs. | €132.76 - 29 % |
from 100 pcs. | €119.49 - 36 % |
Country of origin | D |
---|---|
Item weight | 0.075 kg |
Customs tariff number | 90318020 |
Technical Data
424D11080B
€186.52
|
424D11359
€179.91
|
424D17200
€179.91
|
424D17359
€179.91
|
424D17359B
€186.52
|
424D57359
€217.81
|
||
Electrical data
|
|||||||
Angle measuring range: | 80 ° | 359 ° | 200 ° | 359 ° | 359 ° | 359 ° | |
---|---|---|---|---|---|---|---|
Current consumption: | 30 mA | 30 mA | 30 mA | 30 mA | 30 mA | 30 mA | |
EMC Agricultural and forestry machines (Norm): | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | |
EMC Earth-moving and building construction machinery (Norm): | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | |
EMC Industrial trucks (Norm): | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | |
Linearity error: | < ±1 % | < ±1 % | < ±1 % | < ±1 % | < ±1 % | < ±1 % | |
Load resistance max.: | 200 Ohm | 200 Ohm | - | - | - | - | |
Load resistance min.: | - | - | 100000 Ohm | 100000 Ohm | 100000 Ohm | 100000 Ohm | |
MTTF: | 79.6 a | 79.6 a | 115.9 a | 115.9 a | 115.9 a | 115.9 a | |
Operating voltage max.: | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | |
Operating voltage min.: | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | |
Output signal - centre position/zero position: | 12 mA | 12 mA | - | - | - | - | |
Output signal - centre position/zero position: | - | - | 2.5 V DC | 2.5 V DC | 2.5 V DC | 2.5 V DC | |
Output signal max.: | 20 mA | 20 mA | - | - | - | - | |
Output signal max.: | - | - | 4.5 V DC | 4.5 V DC | 4.5 V DC | 4.5 V DC | |
Output signal min.: | 4 mA | 4 mA | - | - | - | - | |
Output signal min.: | - | - | 0.5 V DC | 0.5 V DC | 0.5 V DC | 0.5 V DC | |
Outputs: | 4...20mA | 4...20mA | 0,5...4,5V | 0,5...4,5V | 0,5...4,5V | 0,5...4,5V | |
Outputs (quantity, type): | 1 | 1 | 1 | 1 | 1 | 2 | |
Polarity reversal protection: | |||||||
Resolution: | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | |
Signal sequence: | CCW | CCW | CCW | CCW | CCW | CW/CCW | |
Signal update rate: | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | |
Technology: | Hall | Hall | Hall | Hall | Hall | Hall | |
Temperature coefficient: | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | |
Mechanical data
|
|||||||
Actuating lever: | |||||||
Max. shaft load, axial: | 50 N | 50 N | 50 N | 50 N | 50 N | 50 N | |
Max. shaft load, radial: | 100 N | 100 N | 100 N | 100 N | 100 N | 100 N | |
Mechanical stop: | |||||||
Material information
|
|||||||
Housing material: | PBT | PBT | PBT | PBT | PBT | PBT | |
Environmental conditions
|
|||||||
Max. operating temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Max. storage temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Min. storage temperature: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Operating temperature min.: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Protection class: | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | |
Installation
|
|||||||
Torque for fastening screws: | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | |
Connection
|
|||||||
Connector type: | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P |
424D11080B
€303.12
Electrical data
Angle measuring range:
80 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
200 Ohm
Load resistance min.:
-
MTTF:
79.6 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D11359
€292.38
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
200 Ohm
Load resistance min.:
-
MTTF:
79.6 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17200
€292.38
Electrical data
Angle measuring range:
200 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17359
€292.38
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17359B
€303.12
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D57359
€353.97
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CW/CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
Documents and Downloads
Instructions