Angle sensor 359° CCW - 424D17359 - 0.5-4.5V
Part number:
Art. -No.
424D17359
per item €179.91
available (18 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 5 pcs. | €170.92 - 5 % |
from 10 pcs. | €158.10 - 12 % |
from 25 pcs. | €142.29 - 21 % |
from 50 pcs. | €128.06 - 29 % |
from 100 pcs. | €115.25 - 36 % |
Product information
Country of origin | D |
---|---|
Item weight | 0.062 kg |
Customs tariff number | 90318020 |
Attention: Please note that the operating lever is NOT included in the scope of delivery for all variants (see technical data)!
Due to the high IP67 protection class, the sensor can also be used in harsh environmental conditions. Because of their robustness, the sensors are particularly suitable for detecting the angular positions of rotational elements under extreme environmental conditions, such as on mobile machinery, in cranes, excavators, ships, mobile and stationary waste compactors, valve control, robotics and wind power plants or in large medical equipment.
Features
-
Long service life and reliability through contactless measuring principle with Hall sensor
-
Angular measurement range from 30° to 120°
-
IP67 protection class for harsh environmental conditions
-
High temperature resistance from -40 °C to +85 °C
-
Resolution 0.1°
-
Various current or voltage output signals
-
Infinitely short-circuit proof
-
Available together with actuation lever for simple connection
-
EMV stabile for the motor vehicle sector, field withstand 200 V/m
-
Ball bearing (optionally with plain bearing)
Technical Data
424D11080B
€186.52
|
424D11359
€179.91
|
424D17200
€179.91
|
424D17359
€179.91
|
424D17359B
€186.52
|
424D57359
€217.81
|
||
Electrical data
|
|||||||
Angle measuring range: | 80 ° | 359 ° | 200 ° | 359 ° | 359 ° | 359 ° | |
---|---|---|---|---|---|---|---|
Current consumption: | 30 mA | 30 mA | 30 mA | 30 mA | 30 mA | 30 mA | |
EMC Agricultural and forestry machines (Norm): | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4 | |
EMC Earth-moving and building construction machinery (Norm): | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute) | |
EMC Industrial trucks (Norm): | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | |
Linearity error: | < ±1 % | < ±1 % | < ±1 % | < ±1 % | < ±1 % | < ±1 % | |
Load resistance max.: | 200 Ohm | 200 Ohm | - | - | - | - | |
Load resistance min.: | - | - | 100000 Ohm | 100000 Ohm | 100000 Ohm | 100000 Ohm | |
MTTF: | 79.6 a | 79.6 a | 115.9 a | 115.9 a | 115.9 a | 115.9 a | |
Operating voltage max.: | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | |
Operating voltage min.: | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | |
Output signal - centre position/zero position: | 12 mA | 12 mA | - | - | - | - | |
Output signal - centre position/zero position: | - | - | 2.5 V DC | 2.5 V DC | 2.5 V DC | 2.5 V DC | |
Output signal max.: | 20 mA | 20 mA | - | - | - | - | |
Output signal max.: | - | - | 4.5 V DC | 4.5 V DC | 4.5 V DC | 4.5 V DC | |
Output signal min.: | 4 mA | 4 mA | - | - | - | - | |
Output signal min.: | - | - | 0.5 V DC | 0.5 V DC | 0.5 V DC | 0.5 V DC | |
Outputs: | 4...20mA | 4...20mA | 0,5...4,5V | 0,5...4,5V | 0,5...4,5V | 0,5...4,5V | |
Outputs (quantity, type): | 1 | 1 | 1 | 1 | 1 | 2 | |
Polarity reversal protection: | |||||||
Resolution: | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | 0.09 ° | |
Signal sequence: | CCW | CCW | CCW | CCW | CCW | CW/CCW | |
Signal update rate: | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | 1600 Hz | |
Technology: | Hall | Hall | Hall | Hall | Hall | Hall | |
Temperature coefficient: | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | < ±1.2 % | |
Mechanical data
|
|||||||
Actuating lever: | |||||||
Max. shaft load, axial: | 50 N | 50 N | 50 N | 50 N | 50 N | 50 N | |
Max. shaft load, radial: | 100 N | 100 N | 100 N | 100 N | 100 N | 100 N | |
Mechanical stop: | |||||||
Material information
|
|||||||
Housing material: | PBT | PBT | PBT | PBT | PBT | PBT | |
Environmental conditions
|
|||||||
Max. operating temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Max. storage temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Min. storage temperature: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Operating temperature min.: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Protection class: | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | |
Installation
|
|||||||
Torque for fastening screws: | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | |
Connection
|
|||||||
Connector type: | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P |
424D11080B
€303.12
Electrical data
Angle measuring range:
80 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
200 Ohm
Load resistance min.:
-
MTTF:
79.6 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D11359
€292.38
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
200 Ohm
Load resistance min.:
-
MTTF:
79.6 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17200
€292.38
Electrical data
Angle measuring range:
200 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17359
€292.38
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D17359B
€303.12
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
1
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424D57359
€353.97
Electrical data
Angle measuring range:
359 °
Current consumption:
30 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 35V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Linearity error:
< ±1 %
Load resistance max.:
-
Load resistance min.:
100000 Ohm
MTTF:
115.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.09 °
Signal sequence:
CW/CCW
Signal update rate:
1600 Hz
Technology:
Hall
Temperature coefficient:
< ±1.2 %
Mechanical data
Actuating lever:
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
Documents and Downloads
Instructions