Angle sensor 120° CCW/CCW 0,5-4,5V | 424RA077P120
Angle sensor 120° CCW/CCW 0,5-4,5V
Angle sensor 120° CCW/CCW 0,5-4,5V
  • Product details
  • Technical Data

Angle sensor 120° CCW/CCW 0,5-4,5V

per item €209.85

out of stock, deliverable in 60 working days

Delivery time could last even longer because of high production capacity.

Quantity Price
from 10 pcs. €188.87 - 10 %
from 25 pcs. €167.88 - 20 %
from 50 pcs. €146.90 - 30 %

Choose variant:

Create offer

out of stock, deliverable in 60 working days

Delivery time could last even longer because of high production capacity.

Technical Data
424RA011G030
€209.85
424RA077P120
€209.85
424RA111G030
€209.85
424RD111G100
€209.85
424RD111P070
€209.85
Electrical data
Angle measuring range: 30 ° 90 ° - 100 ° 70 °
Current consumption: 18 mA 10 mA 18 mA 18 mA 18 mA
EMC Agricultural and forestry machines (Norm): EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm): DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm): DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895
Load resistance max.: 250 Ohm - 1250 Ohm 250 Ohm 250 Ohm
Load resistance min.: - 20000 Ohm 250 Ohm - -
MTTF: 205.9 a 144.5 a - 205.9 a 205.9 a
Operating voltage max.: 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC
Operating voltage min.: 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC
Output signal - centre position/zero position: 12 mA - 12 mA 12 mA 12 mA
Output signal - centre position/zero position: - 2.5 V DC - - -
Output signal max.: 20 mA - 20 mA 20 mA 20 mA
Output signal max.: - 4.5 V DC - - -
Output signal min.: 4 mA - 4 mA 4 mA 4 mA
Output signal min.: - 0.5 V DC - - -
Outputs: 4...20mA 0,5...4,5V 4...20mA 4...20mA 4...20mA
Outputs (quantity, type): 2 2 2 2 2
Polarity reversal protection:
Resolution: 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 °
Signal sequence: CCW/CW (opposite) CCW/CW (opposite) CCW/CW (gegenläufig) CCW/CW (gegenläufig) CCW/CCW
Signal update rate: 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz
Technology: Hall Hall Hall Hall Hall
Temperature coefficient: typ. ±250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K
Typical linearity error: ±5,0°
Mechanical data
Actuating lever: NO YES - NO
Bearing: Plain bearing Ball bearing Ball bearing Ball bearing Ball bearing
Max. shaft load, axial: 50 N 50 N 50 N 50 N 50 N
Max. shaft load, radial: 100 N 100 N 100 N 100 N 100 N
Mechanical stop:
Material information
Housing material: PBT - PBT PBT PBT
Environmental conditions
Max. operating temperature: 85 °C 85 °C 85 °C 85 °C 85 °C
Max. storage temperature: 85 °C 85 °C 85 °C 85 °C 85 °C
Min. storage temperature: -40 °C -40 °C -40 °C -40 °C -40 °C
Operating temperature min.: -40 °C -40 °C -40 °C -40 °C -40 °C
Protection class: IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Installation
Torque for fastening screws: 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m
Connection
Connector type: AMP Micro Quadlock-6P Deutsch DT04-6P AMP Micro Quadlock-6P Deutsch DT04-6P Deutsch DT04-6P
424RA011G030
€209.85
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Plain bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RA077P120
€209.85
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
144.5 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
-
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RA111G030
€209.85
Electrical data
Angle measuring range:
-
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
-
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
-
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RD111G100
€209.85
Electrical data
Angle measuring range:
100 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111P070
€209.85
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P