Angle sensor 070° CCW/CW - 424RD111G070 - 4-20mA | elostore
Angle sensor 070° CCW/CW - 424RD111G070 - 4-20mA
Angle sensor 070° CCW/CW - 424RD111G070 - 4-20mA
  • Product details
  • Technical Data

Angle sensor 070° CCW/CW - 424RD111G070 - 4-20mA

per item €178.79

available (46 pcs.), ships within 1-3 days

Quantity Price
from 5 pcs. €169.85 - 5 %
from 10 pcs. €157.11 - 12 %
from 25 pcs. €141.40 - 21 %
from 50 pcs. €127.26 - 29 %
from 100 pcs. €114.54 - 36 %

Choose variant:

Create offer

available (46 pcs.), ships within 1-3 days

Country of origin D
Item weight 0.067 kg
Customs tariff number 90318020
Technical Data
424RA011G030
€178.79
424RA077P120
€178.79
424RA111G030
€178.79
424RA111P070B
€210.09
424RD111G070
€178.79
424RD111G100
€178.79
424RD111P070
€178.79
424RD111P120B
€187.94
Electrical data
Angle measuring range: 30 ° 90 ° - 70 ° 70 ° 100 ° 70 ° 120 °
Current consumption: 18 mA 10 mA 18 mA 18 mA 18 mA 18 mA 18 mA 18 mA
EMC Agricultural and forestry machines (Norm): EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm): DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm): DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895
Load resistance max.: 250 Ohm - 1250 Ohm 250 Ohm 250 Ohm 250 Ohm 250 Ohm 250 Ohm
Load resistance min.: - 20000 Ohm 250 Ohm - - - - -
MTTF: 205.9 a 144.5 a - 205.9 a 205.9 a 205.9 a 205.9 a 205.9 a
Operating voltage max.: 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC
Operating voltage min.: 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC
Output signal - centre position/zero position: 12 mA - 12 mA 12 mA 12 mA 12 mA 12 mA 12 mA
Output signal - centre position/zero position: - 2.5 V DC - - - - - -
Output signal max.: 20 mA - 20 mA 20 mA 20 mA 20 mA 20 mA 20 mA
Output signal max.: - 4.5 V DC - - - - - -
Output signal min.: 4 mA - 4 mA 4 mA 4 mA 4 mA 4 mA 4 mA
Output signal min.: - 0.5 V DC - - - - - -
Outputs: 4...20mA 0,5...4,5V 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA 4...20mA
Outputs (quantity, type): 2 2 2 2 2 2 2 2
Polarity reversal protection:
Resolution: 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 ° 0.1 °
Signal sequence: CCW/CW (opposite) CCW/CW (opposite) CCW/CW (gegenläufig) CCW/CCW CCW/CW (gegenläufig) CCW/CW (gegenläufig) CCW/CCW CCW/CCW
Signal update rate: 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz 2000 Hz
Technology: Hall Hall Hall Hall Hall Hall Hall Hall
Temperature coefficient: typ. ±250 ppm/K typ. ±250 ppm/K 250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K typ. ±250 ppm/K
Typical linearity error: ±2,0° ±2,0° ±5,0° ±5,0°
Mechanical data
Actuating lever: NO YES - NO
Bearing: Plain bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing Ball bearing
Max. shaft load, axial: 50 N 50 N 50 N 50 N 50 N 50 N 50 N 50 N
Max. shaft load, radial: 100 N 100 N 100 N 100 N 100 N 100 N 100 N 100 N
Mechanical stop:
Material information
Housing material: PBT - PBT PBT PBT PBT PBT PBT
Environmental conditions
Max. operating temperature: 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Max. storage temperature: 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C 85 °C
Min. storage temperature: -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
Operating temperature min.: -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C -40 °C
Protection class: IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Installation
Torque for fastening screws: 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m 2.5 N m
Connection
Connector type: AMP Micro Quadlock-6P Deutsch DT04-6P AMP Micro Quadlock-6P AMP Micro Quadlock-6P Deutsch DT04-6P Deutsch DT04-6P Deutsch DT04-6P Deutsch DT04-6P
424RA011G030
€209.85
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Plain bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RA077P120
€209.85
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
144.5 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
-
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RA111G030
€209.85
Electrical data
Angle measuring range:
-
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
-
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
-
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RA111P070B
€210.09
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RD111G070
€209.85
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111G100
€209.85
Electrical data
Angle measuring range:
100 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111P070
€209.85
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111P120B
€220.59
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P