Angle sensor 120° CCW/CCW - 424RD111P120B - with operating lever - 4-20mA
per item €187.94
available (36 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 5 pcs. | €178.55 - 5 % |
from 10 pcs. | €165.15 - 12 % |
from 25 pcs. | €148.64 - 21 % |
from 50 pcs. | €133.78 - 29 % |
from 100 pcs. | €120.40 - 36 % |
Choose variant:
Country of origin | D |
---|---|
Item weight | 0.056 kg |
Customs tariff number | 90318020 |
Technical Data
424RA011G030
€178.79
|
424RA077P120
€178.79
|
424RA111G030
€178.79
|
424RA111P070B
€210.09
|
424RD111G070
€178.79
|
424RD111G100
€178.79
|
424RD111P070
€178.79
|
424RD111P120B
€187.94
|
||
Electrical data
|
|||||||||
Angle measuring range: | 30 ° | 90 ° | - | 70 ° | 70 ° | 100 ° | 70 ° | 120 ° | |
---|---|---|---|---|---|---|---|---|---|
Current consumption: | 18 mA | 10 mA | 18 mA | 18 mA | 18 mA | 18 mA | 18 mA | 18 mA | |
EMC Agricultural and forestry machines (Norm): | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | [EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4] | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4 | |
EMC Earth-moving and building construction machinery (Norm): | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | [DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)] | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute) | |
EMC Industrial trucks (Norm): | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | DIN EN 12895 | |
Load resistance max.: | 250 Ohm | - | 1250 Ohm | 250 Ohm | 250 Ohm | 250 Ohm | 250 Ohm | 250 Ohm | |
Load resistance min.: | - | 20000 Ohm | 250 Ohm | - | - | - | - | - | |
MTTF: | 205.9 a | 144.5 a | - | 205.9 a | 205.9 a | 205.9 a | 205.9 a | 205.9 a | |
Operating voltage max.: | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | 30 V DC | |
Operating voltage min.: | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | 10 V DC | |
Output signal - centre position/zero position: | 12 mA | - | 12 mA | 12 mA | 12 mA | 12 mA | 12 mA | 12 mA | |
Output signal - centre position/zero position: | - | 2.5 V DC | - | - | - | - | - | - | |
Output signal max.: | 20 mA | - | 20 mA | 20 mA | 20 mA | 20 mA | 20 mA | 20 mA | |
Output signal max.: | - | 4.5 V DC | - | - | - | - | - | - | |
Output signal min.: | 4 mA | - | 4 mA | 4 mA | 4 mA | 4 mA | 4 mA | 4 mA | |
Output signal min.: | - | 0.5 V DC | - | - | - | - | - | - | |
Outputs: | 4...20mA | 0,5...4,5V | 4...20mA | 4...20mA | 4...20mA | 4...20mA | 4...20mA | 4...20mA | |
Outputs (quantity, type): | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Polarity reversal protection: | |||||||||
Resolution: | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° | |
Signal sequence: | CCW/CW (opposite) | CCW/CW (opposite) | CCW/CW (gegenläufig) | CCW/CCW | CCW/CW (gegenläufig) | CCW/CW (gegenläufig) | CCW/CCW | CCW/CCW | |
Signal update rate: | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | |
Technology: | Hall | Hall | Hall | Hall | Hall | Hall | Hall | Hall | |
Temperature coefficient: | typ. ±250 ppm/K | typ. ±250 ppm/K | 250 ppm/K | typ. ±250 ppm/K | typ. ±250 ppm/K | typ. ±250 ppm/K | typ. ±250 ppm/K | typ. ±250 ppm/K | |
Typical linearity error: | ±2,0° | ±2,0° | ±5,0° | ±5,0° | |||||
Mechanical data
|
|||||||||
Actuating lever: | NO | YES | - | NO | |||||
Bearing: | Plain bearing | Ball bearing | Ball bearing | Ball bearing | Ball bearing | Ball bearing | Ball bearing | Ball bearing | |
Max. shaft load, axial: | 50 N | 50 N | 50 N | 50 N | 50 N | 50 N | 50 N | 50 N | |
Max. shaft load, radial: | 100 N | 100 N | 100 N | 100 N | 100 N | 100 N | 100 N | 100 N | |
Mechanical stop: | |||||||||
Material information
|
|||||||||
Housing material: | PBT | - | PBT | PBT | PBT | PBT | PBT | PBT | |
Environmental conditions
|
|||||||||
Max. operating temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Max. storage temperature: | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | 85 °C | |
Min. storage temperature: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Operating temperature min.: | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
Protection class: | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | |
Installation
|
|||||||||
Torque for fastening screws: | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | 2.5 N m | |
Connection
|
|||||||||
Connector type: | AMP Micro Quadlock-6P | Deutsch DT04-6P | AMP Micro Quadlock-6P | AMP Micro Quadlock-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P | Deutsch DT04-6P |
424RA011G030
€209.85
Electrical data
Angle measuring range:
30 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Plain bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RA077P120
€209.85
Electrical data
Angle measuring range:
90 °
Current consumption:
10 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
-
Load resistance min.:
20000 Ohm
MTTF:
144.5 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
-
Output signal - centre position/zero position:
2.5 V DC
Output signal max.:
-
Output signal max.:
4.5 V DC
Output signal min.:
-
Output signal min.:
0.5 V DC
Outputs:
0,5...4,5V
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (opposite)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
YES
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
-
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RA111G030
€209.85
Electrical data
Angle measuring range:
-
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
[EN ISO 14982,pulse 5b: max. voltage 35V (absolute), functional status C for pulse 1 and 4]
EMC Earth-moving and building construction machinery (Norm):
[DIN EN ISO 13766-1,pulse "load dump"; ´max. voltage 35V (absolute)]
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
1250 Ohm
Load resistance min.:
250 Ohm
MTTF:
-
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
-
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RA111P070B
€210.09
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
AMP Micro Quadlock-6P
424RD111G070
€209.85
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±2,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111G100
€209.85
Electrical data
Angle measuring range:
100 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CW (gegenläufig)
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111P070
€209.85
Electrical data
Angle measuring range:
70 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
Mechanical data
Actuating lever:
NO
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
424RD111P120B
€220.59
Electrical data
Angle measuring range:
120 °
Current consumption:
18 mA
EMC Agricultural and forestry machines (Norm):
EN ISO 14982<br>pulse 5b: max. voltage 56V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1<br>pulse "load dump": max. voltage 56V (absolute)
EMC Industrial trucks (Norm):
DIN EN 12895
Load resistance max.:
250 Ohm
Load resistance min.:
-
MTTF:
205.9 a
Operating voltage max.:
30 V DC
Operating voltage min.:
10 V DC
Output signal - centre position/zero position:
12 mA
Output signal - centre position/zero position:
-
Output signal max.:
20 mA
Output signal max.:
-
Output signal min.:
4 mA
Output signal min.:
-
Outputs:
4...20mA
Outputs (quantity, type):
2
Polarity reversal protection:
Resolution:
0.1 °
Signal sequence:
CCW/CCW
Signal update rate:
2000 Hz
Technology:
Hall
Temperature coefficient:
typ. ±250 ppm/K
Typical linearity error:
±5,0°
Mechanical data
Actuating lever:
Bearing:
Ball bearing
Max. shaft load, axial:
50 N
Max. shaft load, radial:
100 N
Mechanical stop:
Material information
Housing material:
PBT
Environmental conditions
Max. operating temperature:
85 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-40 °C
Operating temperature min.:
-40 °C
Protection class:
IP67 DIN EN 60529
Installation
Torque for fastening screws:
2.5 N m
Connection
Connector type:
Deutsch DT04-6P
Documents and Downloads
Instructions