Tilt sensor - N7 dynamic - N7DCC0D2H2-001 - Deutsch - ±90/±180-5/10-A/A | N7DCC0D2H2-001
Tilt sensor - N7 dynamic - N7DCC0D2H2-001 - Deutsch - ±90/±180-5/10-A/A
Tilt sensor - N7 dynamic - N7DCC0D2H2-001 - Deutsch - ±90/±180-5/10-A/A
  • Product details
  • Technical Data

Tilt sensor - N7 dynamic - N7DCC0D2H2-001 - Deutsch - ±90/±180-5/10-A/A

per item €427.50

out of stock, deliverable in 60 working days

Delivery time could last even longer because of high production capacity.

Quantity Price
from 3 pcs. €384.75 - 10 %
from 5 pcs. €342.00 - 20 %
from 10 pcs. €299.25 - 30 %
from 25 pcs. €277.88 - 35 %

Choose variant:

Create offer

out of stock, deliverable in 60 working days

Delivery time could last even longer because of high production capacity.

Product information
New N7 dynamic tilt sensor generation

The N7 dynamic provides a precise measurement signal on mobile machinery, even in the event of jerky movements, vibrations and shocks.

In addition to MEMS technology (microelectromechanical systems), the N7 dynamic inclination sensor is equipped with Sensor Fusion, an extremely responsive combination of acceleration sensor and gyroscope. This significantly reduces the negative effects of jerky movements and ensures the provision of precise measurement data.

The field of application for the inclination sensors ranges from agricultural and construction machinery to industrial trucks. The N7 dynamic is particularly suitable for dynamic machines such as excavators, dump trucks or self-propelled sprayers. The available connector variants offer a suitable solution for every requirement.
Features
  • Precise and continuous measurement of the tilt angle of mobile machinery
  • Robust design for a long service life: protection class IP67 / IP69K [ISO 20653)
  • Simple variant management thanks to clever modular system
  • Up to 30% faster installation than with existing inclination sensors thanks to efficient 2-point mounting
Technical Data
N7DCC000H2-001
€427.50
N7DCC000V2-001
€427.50
N7DCC001H2-001
€442.50
N7DCC001V2-001
€442.50
N7DCC002H2-001
€412.50
N7DCC002V2-001
€412.50
N7DCC0D2H2-001
€427.50
N7DCJ000H2-001
€427.50
N7DCJ000V2-001
€427.50
N7DCJ001H2-001
€442.50
N7DCJ001V2-001
€442.50
N7DCJ002H2-001
€412.50
N7DCJ002V2-001
€412.50
N7DCJ0D2H2-001
€427.50
N7DCJ0D2V2-001
€427.50
NMT autostart: not active not active not active not active not active not active not active not active not active not active not active not active not active not active not active
Electrical data
Accuracy dynamically typ.: ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 ° ±0,5 °
Baud rate: 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s 250 kBit/s
Bus terminating resistor:
Connection type (switching output): - - - - - - Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4) - - - - - - Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4) Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4)
Contact form: - - - - - - NC - - - - - - NC NC
Current consumption: < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA < 100 mA
Cycle time: 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms
EMC Agricultural and forestry machines (Norm): EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm): DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4 DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm): DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895 DIN EN 12895
Hysteresis: - - - - - - ±0,1° - - - - - - ±0,1° ±0,1°
Initialisation time after power on/start-up time: 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms 500 ms
MTTF: 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a 92 a
Max. switching current: - - - - - - 1 A - - - - - - 1 A 1 A
Max. switching power: - - - - - - 30 W - - - - - - 30 W 30 W
Max. switching voltage: - - - - - - 36 V DC - - - - - - 36 V DC 36 V DC
Measuring principle: dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications) dynamic /(fast) moving applications)
Measuring range: ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse ±90° X-Achse<br>±180° Y-Achse ±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.: ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g ±8 g
Measuring range gyroscope max.: ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s ±250 °/s
Node ID / Source Address: 32 32 32 32 32 32 32 226 226 226 226 226 226 226 226
Number of measurement axes (Number): 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Number of measurement axes tilt: 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Output signal: CANopen CANopen CANopen CANopen CANopen CANopen CANopen + 2x realy (NC) CANopen + 2x relay (NC) J1939 J1939 J1939 J1939 J1939 J1939 J1939 + 2x relay (NC) J1939 + 2x relay (NC)
Polarity reversal protection: -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC -36 V DC
Protocol: CANopen CANopen CANopen CANopen CANopen CANopen CANopen J1939 J1939 J1939 J1939 J1939 J1939 J1939 J1939
Repeating accuracy: ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 ° ±0,2 ° typ. ±0,2 °
Resolution: 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 ° 0,01 °
Sensing rate: 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz
Short-circuit protection: ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2 ISO 16750-2
Supply voltage: +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC +8..+36 V DC
Switching points: - - - - - - X1/X3 = 5°<br>X2/X4 = 10°<br>Y1/Y3 = 5°<br>Y2/Y4 = 10° ° - - - - - - X1/X3 = 5°<br>X2/X4 = 10°<br>Y1/Y3 = 5°<br>Y2/Y4 = 10° ° X1/X3 = 5°<br>X2/X4 = 10°<br>Z1/Z3 = 5°<br>Z2/Z4 = 10° °
Technology: MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS MEMS
Temperature coefficient: max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K max. ±0,015°/K ±0,015°/K
Turn-off delay: - - - - - - 0s - - - - - - 0s 0s
Turn-on delay: - - - - - - 0s - - - - - - 0s 0s
UDS ISO 14229 capability:
Zero justification: ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60° ±60°
Mechanical data
Torque for fastening screws: 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm 10 Nm
Material information
Housing material: PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT PBT GF30 PBT
Environmental conditions
Operating temperature: -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C -40..+85 °C -20..+85 °C
Protection class: IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653 IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test: DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C) DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm): EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms) EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature: -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C -40..+85 °C
Vibration resistance (Norm): EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement) EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation: horizontal vertically horizontal vertically horizontal vertically horizontal horizontal vertically horizontal vertically horizontal vertically horizontal vertically
Weight: 113 g 108 g 113 g 123 g 123 g 108 g 108 g 108 g 113 g 113 g 123 g 123 g 108 g 108 g 108 g 180 g
Connection
Connector type: 1xM12 5-polig (male) 1xM12 Deutsch DT04-08PA 1xM12 5-polig (male) 1xM12 2xM12 5-polig (male/female) 2xM12 2xM12 5-polig (male/female) 2xM12 Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA 1xM12 5-polig (male) 1xM12 1xM12 5-polig (male) 1xM12 2xM12 5-polig (male/female) 2xM12 2xM12 5-polig (male/female) 2xM12 Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA Deutsch DT04-08PA
N7DCC000H2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
113 g 108 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12 Deutsch DT04-08PA
N7DCC000V2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
113 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12
N7DCC001H2-001
€442.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
123 g
Connection
Connector type:
2xM12 5-polig (male/female) 2xM12
N7DCC001V2-001
€442.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
123 g
Connection
Connector type:
2xM12 5-polig (male/female) 2xM12
N7DCC002H2-001
€412.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCC002V2-001
€412.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCC0D2H2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4)
Contact form:
NC
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
±0,1°
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
1 A
Max. switching power:
30 W
Max. switching voltage:
36 V DC
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
32
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
CANopen + 2x realy (NC) CANopen + 2x relay (NC)
Polarity reversal protection:
-36 V DC
Protocol:
CANopen
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
X1/X3 = 5°<br>X2/X4 = 10°<br>Y1/Y3 = 5°<br>Y2/Y4 = 10° °
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
0s
Turn-on delay:
0s
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCJ000H2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
113 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12
N7DCJ000V2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
113 g
Connection
Connector type:
1xM12 5-polig (male) 1xM12
N7DCJ001H2-001
€442.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
123 g
Connection
Connector type:
2xM12 5-polig (male/female) 2xM12
N7DCJ001V2-001
€442.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
123 g
Connection
Connector type:
2xM12 5-polig (male/female) 2xM12
N7DCJ002H2-001
€412.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCJ002V2-001
€412.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
-
Contact form:
-
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
-
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
-
Max. switching power:
-
Max. switching voltage:
-
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
-
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
-
Turn-on delay:
-
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCJ0D2H2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4)
Contact form:
NC
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
±0,1°
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
1 A
Max. switching power:
30 W
Max. switching voltage:
36 V DC
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Y-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939 + 2x relay (NC)
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
X1/X3 = 5°<br>X2/X4 = 10°<br>Y1/Y3 = 5°<br>Y2/Y4 = 10° °
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
0s
Turn-on delay:
0s
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
horizontal
Weight:
108 g
Connection
Connector type:
Deutsch DT04-08PA
N7DCJ0D2V2-001
€427.50
NMT autostart:
not active
Electrical data
Accuracy dynamically typ.:
±0,5 °
Baud rate:
250 kBit/s
Bus terminating resistor:
Connection type (switching output):
Relay 1 = X1/X3 Y1/Y3 (Z1/Z3) / Relay 2 = X2/X4 Y2/Y4 (Z2/Z4)
Contact form:
NC
Current consumption:
< 100 mA
Cycle time:
10 ms
EMC Agricultural and forestry machines (Norm):
EN ISO 14982, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Earth-moving and building construction machinery (Norm):
DIN EN ISO 13766-1, Load dump Pulse B with Us = 85V, Cranking ISO 16750-2 Level 1-4
EMC Industrial trucks (Norm):
DIN EN 12895
Hysteresis:
±0,1°
Initialisation time after power on/start-up time:
500 ms
MTTF:
92 a
Max. switching current:
1 A
Max. switching power:
30 W
Max. switching voltage:
36 V DC
Measuring principle:
dynamic /(fast) moving applications)
Measuring range:
±90° X-Achse<br>±180° Z-Achse
Measuring range acceleration max.:
±8 g
Measuring range gyroscope max.:
±250 °/s
Node ID / Source Address:
226
Number of measurement axes (Number):
2
Number of measurement axes tilt:
2
Output signal:
J1939 + 2x relay (NC)
Polarity reversal protection:
-36 V DC
Protocol:
J1939
Repeating accuracy:
±0,2 ° typ. ±0,2 °
Resolution:
0,01 °
Sensing rate:
100 Hz
Short-circuit protection:
ISO 16750-2
Supply voltage:
+8..+36 V DC
Switching points:
X1/X3 = 5°<br>X2/X4 = 10°<br>Z1/Z3 = 5°<br>Z2/Z4 = 10° °
Technology:
MEMS
Temperature coefficient:
max. ±0,015°/K ±0,015°/K
Turn-off delay:
0s
Turn-on delay:
0s
UDS ISO 14229 capability:
Zero justification:
±60°
Mechanical data
Torque for fastening screws:
10 Nm
Material information
Housing material:
PBT GF30 PBT
Environmental conditions
Operating temperature:
-40..+85 °C -20..+85 °C
Protection class:
IP6K7 ISO 20653, IP6K9K ISO 20653
Salt spray test:
DIN EN 60068-2-11 (salt spray mist for 96h at 35°C)
Shock resistance (Norm):
EN 60068-2-27 (shock 51g, 11ms) EN 60068-2-27 (schock 51g, 11ms)
Storage temperature:
-40..+85 °C
Vibration resistance (Norm):
EN 60068-2-64 (random vibration 7,99g , 5-500Hz, 20,1mm displacement)
Installation
Installation:
vertically
Weight:
180 g
Connection
Connector type:
Deutsch DT04-08PA