eloProg output expans. unit relay/bus capable
Part number:
Art. -No.
485EPR04S00B
per item €954.27
out of stock, deliverable in 60 business days
Quantity | Price |
---|---|
from 3 pcs. | €858.84 - 10 % |
from 5 pcs. | €763.42 - 20 % |
from 10 pcs. | €667.99 - 30 % |
from 25 pcs. | €620.28 - 35 % |
Country of origin | I |
---|---|
Item weight | 0.1 kg |
Customs tariff number | 85371091 |
Technical Data
485EPR04
€563.88
|
485EPR04S00B
€954.27
|
||
|
|||
Connection to output module: | - | via connection terminals | |
---|---|---|---|
Electrical data
|
|||
Feedback circuit: | Depending on the configuration | Depending on the configuration | |
LED display: | single-coloured two-coloured | four-coloured | |
Max. switching current at safety output: | 6 A | 6 A | |
Max. switching voltage at safety output: | 230 V AC | 240 V AC | |
Max. switching voltage at safety output: | 250 V DC | 250 V DC | |
Min. switching current at safety output: | 0.02 A | 0.02 A | |
Min. switching voltage at safety output: | 10 V DC | 10 V DC | |
Min. switching voltage at safety output: | 10 V AC | 10 V AC | |
Number of relay safety outputs: | 6 4 | 4 | |
Operating voltage max.: | 28.8 V DC | 28.8 V DC | |
Operating voltage min.: | 19.2 V DC | 19.2 V DC | |
Power consumption: | 3 W | 3 W | |
Response time: | 12 ms | 12 ms | |
Utilization category: | AC-15 / DC-13 AC-15 4A 230V / DC-13 4A 24V | - | |
Safety-related characteristics
|
|||
DC: | Depending on the configuration % | Depending on the configuration % | |
Max no operating cycles at 1A switching current AC15 230V(B10d): | 750000 | - | |
Max no operating cycles at 2A switching current DC13 24V (B10d): | 10000000 | - | |
Max no operating cycles at 3A switching current AC15 230V(B10d): | 300000 | - | |
Operating life: | 20 Tm | 20 Tm | |
PFHD according to IEC 61508: | depending on the configuration 1/h | 2,72 x 10-9 1/h 2,9 x 10-9 1/h | |
PL acc. to EN ISO 13849-1: | e | e | |
SIL CL acc. to IEC 62061: | 3 | 3 | |
SIL acc. to IEC 61508: | 3 | 3 | |
Safe Failure Fraction (SFF) to IEC 61508: | - | 99.9 % | |
Mechanical data
|
|||
Dimensions: | 108 x 22,5 x 114,5 mm (H/B/T) | 108 x 22,5 x 114,5 mm (H/B/T) | |
Service life, mechanical (Cycles): | > 20 x 10^6 | > 40 x 10^6 | |
Material information
|
|||
Housing colour: | Gehaeuse schwarz Frontplatte gelb | Gehaeuse schwarz Frontplatte gelb | |
Housing material: | PA | PA | |
Environmental conditions
|
|||
Max. operating temperature: | 55 °C | 55 °C | |
Max. storage temperature: | 85 °C | 85 °C | |
Min. storage temperature: | -20 °C | -20 °C | |
Operating temperature min.: | -10 °C | -10 °C | |
Protection class, housing: | IP20 DIN EN 60529 | IP20 DIN EN 60529 | |
Relative humidity: | 10...95 % | 10...95 % | |
Installation
|
|||
Mounting type: | Mounting rail | Mounting rail | |
Torque for connection terminals: | 0.6 N m | 0.6 N m | |
Weight: | 150 g 231 g | 150 g 231 g | |
Connection
|
|||
Connection to base module: | via connection terminals | propriertary 5-way bus (T-connector) | |
Max. connection cross section: | 2.5 mm^2 | 2.5 mm^2 | |
Min. connection cross section: | 0.5 mm^2 | 0.5 mm^2 | |
Pluggable connection terminals: | |||
Screw terminals: | |||
Approvals
|
|||
CE label: | |||
Certified in accordance with: | EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 | EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 |
485EPR04
€563.88
Connection to output module:
-
Electrical data
Feedback circuit:
Depending on the configuration
LED display:
single-coloured
two-coloured
Max. switching current at safety output:
6 A
Max. switching voltage at safety output:
230 V AC
Max. switching voltage at safety output:
250 V DC
Min. switching current at safety output:
0.02 A
Min. switching voltage at safety output:
10 V DC
Min. switching voltage at safety output:
10 V AC
Number of relay safety outputs:
6
4
Operating voltage max.:
28.8 V DC
Operating voltage min.:
19.2 V DC
Power consumption:
3 W
Response time:
12 ms
Utilization category:
AC-15 / DC-13
AC-15 4A 230V / DC-13 4A 24V
Safety-related characteristics
DC:
Depending on the configuration %
Max no operating cycles at 1A switching current AC15 230V(B10d):
750000
Max no operating cycles at 2A switching current DC13 24V (B10d):
10000000
Max no operating cycles at 3A switching current AC15 230V(B10d):
300000
Operating life:
20 Tm
PFHD according to IEC 61508:
depending on the configuration 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Safe Failure Fraction (SFF) to IEC 61508:
-
Mechanical data
Dimensions:
108 x 22,5 x 114,5 mm (H/B/T)
Service life, mechanical (Cycles):
> 20 x 10^6
Material information
Housing colour:
Gehaeuse schwarz Frontplatte gelb
Housing material:
PA
Environmental conditions
Max. operating temperature:
55 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-20 °C
Operating temperature min.:
-10 °C
Protection class, housing:
IP20 DIN EN 60529
Relative humidity:
10...95 %
Installation
Mounting type:
Mounting rail
Torque for connection terminals:
0.6 N m
Weight:
150 g
231 g
Connection
Connection to base module:
via connection terminals
Max. connection cross section:
2.5 mm^2
Min. connection cross section:
0.5 mm^2
Pluggable connection terminals:
Screw terminals:
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
485EPR04S00B
€954.27
Connection to output module:
via connection terminals
Electrical data
Feedback circuit:
Depending on the configuration
LED display:
four-coloured
Max. switching current at safety output:
6 A
Max. switching voltage at safety output:
240 V AC
Max. switching voltage at safety output:
250 V DC
Min. switching current at safety output:
0.02 A
Min. switching voltage at safety output:
10 V DC
Min. switching voltage at safety output:
10 V AC
Number of relay safety outputs:
4
Operating voltage max.:
28.8 V DC
Operating voltage min.:
19.2 V DC
Power consumption:
3 W
Response time:
12 ms
Utilization category:
-
Safety-related characteristics
DC:
Depending on the configuration %
Max no operating cycles at 1A switching current AC15 230V(B10d):
-
Max no operating cycles at 2A switching current DC13 24V (B10d):
-
Max no operating cycles at 3A switching current AC15 230V(B10d):
-
Operating life:
20 Tm
PFHD according to IEC 61508:
2,72 x 10-9 1/h
2,9 x 10-9 1/h
PL acc. to EN ISO 13849-1:
e
SIL CL acc. to IEC 62061:
3
SIL acc. to IEC 61508:
3
Safe Failure Fraction (SFF) to IEC 61508:
99.9 %
Mechanical data
Dimensions:
108 x 22,5 x 114,5 mm (H/B/T)
Service life, mechanical (Cycles):
> 40 x 10^6
Material information
Housing colour:
Gehaeuse schwarz Frontplatte gelb
Housing material:
PA
Environmental conditions
Max. operating temperature:
55 °C
Max. storage temperature:
85 °C
Min. storage temperature:
-20 °C
Operating temperature min.:
-10 °C
Protection class, housing:
IP20 DIN EN 60529
Relative humidity:
10...95 %
Installation
Mounting type:
Mounting rail
Torque for connection terminals:
0.6 N m
Weight:
150 g
231 g
Connection
Connection to base module:
propriertary 5-way bus (T-connector)
Max. connection cross section:
2.5 mm^2
Min. connection cross section:
0.5 mm^2
Pluggable connection terminals:
Screw terminals:
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2