Safety sensor - 114270A0D - magnetically actuated - N.O./N.C, built-in connector M8
Part number:
Art. -No.
114270A0D
per item €79.35
out of stock, deliverable in 60 working days
Quantity | Price |
---|---|
from 25 pcs. | €71.42 - 10 % |
from 50 pcs. | €63.48 - 20 % |
from 100 pcs. | €55.55 - 30 % |
Product information
Country of origin | D |
---|---|
Item weight | 0.02 kg |
Customs tariff number | 85365019 |
The magnetic safety sensors are used to monitor moving guards such as guard doors, hoods or covers. The contactless, and therefore, wear-free sensors meet requirements for long service life, compact size, as well as hygiene, and give the user more flexibility when creating a machine concept.
elobau has designed safety sensors in stainless steel or plastic especially for monitoring guard doors of food processing machinery, which, due to their thermal stability and resistance to cleaning agents, are ideally suited for use in hygienic and wet areas.
Features
-
Cubic and cylindrical versions
-
Metal and plastic versions
-
Versions for increased temperature range
-
Variants/ versions for increased switching distance
-
Available with ETL/CSA approval
-
Protection class up to IP69K
-
Concealed installation possible
Downloads "Safety sensor - 114270A0D - magnetically actuated - N.O./N.C, built-in connector M8"
Technical Data
114262A01
€84.03
|
114270
€78.69
|
114270A0D
€79.35
|
114570
€84.87
|
114V62A0D
€79.35
|
||
Electrical data
|
||||||
Actuation: | see technical drawing | front | front | front | front | |
---|---|---|---|---|---|---|
Assured switch-off distance (Sar): | - | 19 mm | 19 mm | 22 mm | 15 mm | |
Assured switching distance (Sao): | - | 7 mm | 7 mm | 4 mm | 7 mm | |
Contact form: | NO/NO | NO/NC | NO/NC | NO/NC/NO (Kontrollkontakt) | NO/NO | |
LED display: | - | No | No | No | No | |
Max. switching current: | 0.1 A | 0.1 A | 0.1 A | 0.1 A | 0.1 A | |
Max. switching power: | 3 W | 3 W | 3 W | 3 W | 3 W | |
Max. switching voltage: | 28.8 V DC | 28.8 V DC | 28.8 V DC | 28.8 V DC | 28.8 V DC | |
Min. switching voltage: | 19.2 V DC | 19.2 V DC | 19.2 V DC | 19.2 V DC | 19.2 V DC | |
Minimum switching distance (S0 min): | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | 0.5 mm | |
Pollution degree: | - | 3 | 3 | 3 | 3 | |
Protection class: | - | III | III | III | III | |
Series resistor: | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | 22 Ohm | |
Switching frequency: | - | 5 Hz | 5 Hz | 5 Hz | 5 Hz | |
Switching principle: | magnetic | magnetic | magnetic | magnetic | magnetic | |
Technology: | Reed | Reed | Reed | Reed | Reed | |
Safety-related characteristics
|
||||||
B10d acc. to EN ISO 13849-1: | 20000000 | 20000000 | 20000000 | 20000000 | 20000000 | |
Coding acc. to EN ISO 14119: | Low | Low | Low | Low | Low | |
Mission time in years: | - | 20 a | 20 a | 20 a | 20 a | |
Structure acc. to EN ISO 13849-1: | Two-channel | Two-channel | Two-channel | Two-channel | Two-channel | |
Type acc. to EN ISO 14119: | 4 | 4 | 4 | 4 | 4 | |
Mechanical data
|
||||||
Detent present: | ||||||
Dimensions: | 50x25x10 | 25 x 50 x 10 mm | 50 x 25 x 10 mm | 50 x 25 x 10 mm | 50 x 25 x 10 mm | |
Housing design: | rectangular | rectangular | rectangular | rectangular | rectangular | |
cannot be mounted flush: | ||||||
Material information
|
||||||
Cable material: | - | PVC | - | PVC | - | |
Housing colour: | schwarz | schwarz | schwarz | schwarz | schwarz | |
Housing material: | PBT | PBT | PBT | PBT | PBT | |
Environmental conditions
|
||||||
Max. cable temperature range, fixed installation: | 70 °C | 70 °C | - | 105 °C | 70 °C | |
Max. cable temperature range, moving: | 70 °C | 70 °C | - | 105 °C | 70 °C | |
Max. operating temperature: | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | |
Max. storage temperature: | 75 °C | 75 °C | 75 °C | 75 °C | 75 °C | |
Min. cable temperature range, fixed installation: | 25 °C | 25 °C | - | -30 °C | 25 °C | |
Min. cable temperature range, moving: | 5 °C | 5 °C | - | -10 °C | 5 °C | |
Min. storage temperature: | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | |
Operating temperature min.: | -25 °C | -25 °C | -25 °C | -25 °C | -25 °C | |
Protection class: | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | IP67 DIN EN 60529 | |
Protection class, connector: | IP67 DIN EN 60529 | - | IP67 DIN EN 60529 (screwed) - IP65 DIN EN 60529 (plugged) IP67 DIN EN 60529 (geschraubt) - IP65 DIN EN 60529 (gesteckt) | - | IP67 DIN EN 60529 (screwed) - IP65 DIN EN 60529 (plugged) IP67 DIN EN 60529 (geschraubt) - IP65 DIN EN 60529 (gesteckt) | |
Shock resistance (Norm): | - | 30g / 11ms | 30g / 11ms | 30g / 11ms | 30g / 11ms | |
Vibration resistance (Norm): | 10 - 55 Hz | 10 - 55Hz | 10 - 55Hz | 10 - 55Hz | 10 - 55Hz | |
Installation
|
||||||
Installation: | arbitrary | arbitrary | arbitrary | arbitrary | arbitrary | |
Mounting type: | screwed from above | screwed | screwed | screwed | screwed | |
Weight: | 47 g | 47 g | 22 g | - | 47 g | |
Connection
|
||||||
Cable colour: | grau | grau | - | - | grau | |
Cable length: | - | 1 m | - | 1 m | - | |
Cable type: | LIYY 3x0,25 | LIYY 4x0,25 | - | - | LIYY 4x0,25 | |
Connector type: | M8x1 - 3 polig | - | M8x1 - 4 polig | - | M8x1 - 4 polig | |
Number of strands: | 3 | 4 | - | 6 | - | |
Wire cross section: | 0.25 mm^2 | 0.25 mm^2 | - | 0.14 mm^2 | - | |
Approvals
|
||||||
CE label: | ||||||
Certified in accordance with: | ETL | ETL | ETL | - | ETL | |
Operating data
|
||||||
Possible actuators: | 30427532 / 30427502 | 30427532 | 30427532 | 30427532 | 30427532 |
114262A01
€84.03
Electrical data
Actuation:
see technical drawing
Assured switch-off distance (Sar):
-
Assured switching distance (Sao):
-
Contact form:
NO/NO
LED display:
-
Max. switching current:
0.1 A
Max. switching power:
3 W
Max. switching voltage:
28.8 V DC
Min. switching voltage:
19.2 V DC
Minimum switching distance (S0 min):
0.5 mm
Pollution degree:
-
Protection class:
-
Series resistor:
22 Ohm
Switching frequency:
-
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Mission time in years:
-
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
50x25x10
Housing design:
rectangular
cannot be mounted flush:
Material information
Cable material:
-
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, fixed installation:
70 °C
Max. cable temperature range, moving:
70 °C
Max. operating temperature:
75 °C
Max. storage temperature:
75 °C
Min. cable temperature range, fixed installation:
25 °C
Min. cable temperature range, moving:
5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
IP67 DIN EN 60529
Shock resistance (Norm):
-
Vibration resistance (Norm):
10 - 55 Hz
Installation
Installation:
arbitrary
Mounting type:
screwed from above
Weight:
47 g
Connection
Cable colour:
grau
Cable length:
-
Cable type:
LIYY 3x0,25
Connector type:
M8x1 - 3 polig
Number of strands:
3
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
ETL
Operating data
Possible actuators:
30427532 / 30427502
114270
€78.69
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
19 mm
Assured switching distance (Sao):
7 mm
Contact form:
NO/NC
LED display:
No
Max. switching current:
0.1 A
Max. switching power:
3 W
Max. switching voltage:
28.8 V DC
Min. switching voltage:
19.2 V DC
Minimum switching distance (S0 min):
0.5 mm
Pollution degree:
3
Protection class:
III
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
25 x 50 x 10 mm
Housing design:
rectangular
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, fixed installation:
70 °C
Max. cable temperature range, moving:
70 °C
Max. operating temperature:
75 °C
Max. storage temperature:
75 °C
Min. cable temperature range, fixed installation:
25 °C
Min. cable temperature range, moving:
5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 - 55Hz
Installation
Installation:
arbitrary
Mounting type:
screwed
Weight:
47 g
Connection
Cable colour:
grau
Cable length:
1 m
Cable type:
LIYY 4x0,25
Connector type:
-
Number of strands:
4
Wire cross section:
0.25 mm^2
Approvals
CE label:
Certified in accordance with:
ETL
Operating data
Possible actuators:
30427532
114270A0D
€79.35
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
19 mm
Assured switching distance (Sao):
7 mm
Contact form:
NO/NC
LED display:
No
Max. switching current:
0.1 A
Max. switching power:
3 W
Max. switching voltage:
28.8 V DC
Min. switching voltage:
19.2 V DC
Minimum switching distance (S0 min):
0.5 mm
Pollution degree:
3
Protection class:
III
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
50 x 25 x 10 mm
Housing design:
rectangular
cannot be mounted flush:
Material information
Cable material:
-
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, fixed installation:
-
Max. cable temperature range, moving:
-
Max. operating temperature:
75 °C
Max. storage temperature:
75 °C
Min. cable temperature range, fixed installation:
-
Min. cable temperature range, moving:
-
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
IP67 DIN EN 60529 (screwed) - IP65 DIN EN 60529 (plugged)
IP67 DIN EN 60529 (geschraubt) - IP65 DIN EN 60529 (gesteckt)
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 - 55Hz
Installation
Installation:
arbitrary
Mounting type:
screwed
Weight:
22 g
Connection
Cable colour:
-
Cable length:
-
Cable type:
-
Connector type:
M8x1 - 4 polig
Number of strands:
-
Wire cross section:
-
Approvals
CE label:
Certified in accordance with:
ETL
Operating data
Possible actuators:
30427532
114570
€84.87
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
22 mm
Assured switching distance (Sao):
4 mm
Contact form:
NO/NC/NO (Kontrollkontakt)
LED display:
No
Max. switching current:
0.1 A
Max. switching power:
3 W
Max. switching voltage:
28.8 V DC
Min. switching voltage:
19.2 V DC
Minimum switching distance (S0 min):
0.5 mm
Pollution degree:
3
Protection class:
III
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
50 x 25 x 10 mm
Housing design:
rectangular
cannot be mounted flush:
Material information
Cable material:
PVC
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, fixed installation:
105 °C
Max. cable temperature range, moving:
105 °C
Max. operating temperature:
75 °C
Max. storage temperature:
75 °C
Min. cable temperature range, fixed installation:
-30 °C
Min. cable temperature range, moving:
-10 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 - 55Hz
Installation
Installation:
arbitrary
Mounting type:
screwed
Weight:
-
Connection
Cable colour:
-
Cable length:
1 m
Cable type:
-
Connector type:
-
Number of strands:
6
Wire cross section:
0.14 mm^2
Approvals
CE label:
Certified in accordance with:
-
Operating data
Possible actuators:
30427532
114V62A0D
€79.35
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
15 mm
Assured switching distance (Sao):
7 mm
Contact form:
NO/NO
LED display:
No
Max. switching current:
0.1 A
Max. switching power:
3 W
Max. switching voltage:
28.8 V DC
Min. switching voltage:
19.2 V DC
Minimum switching distance (S0 min):
0.5 mm
Pollution degree:
3
Protection class:
III
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
50 x 25 x 10 mm
Housing design:
rectangular
cannot be mounted flush:
Material information
Cable material:
-
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, fixed installation:
70 °C
Max. cable temperature range, moving:
70 °C
Max. operating temperature:
75 °C
Max. storage temperature:
75 °C
Min. cable temperature range, fixed installation:
25 °C
Min. cable temperature range, moving:
5 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
IP67 DIN EN 60529 (screwed) - IP65 DIN EN 60529 (plugged)
IP67 DIN EN 60529 (geschraubt) - IP65 DIN EN 60529 (gesteckt)
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 - 55Hz
Installation
Installation:
arbitrary
Mounting type:
screwed
Weight:
47 g
Connection
Cable colour:
grau
Cable length:
-
Cable type:
LIYY 4x0,25
Connector type:
M8x1 - 4 polig
Number of strands:
-
Wire cross section:
-
Approvals
CE label:
Certified in accordance with:
ETL
Operating data
Possible actuators:
30427532
Documents and Downloads
Instructions
Data sheets