Safety sensor ATEX - 671V62K40-10- N.O./N.O., 10m cable | elostore
Safety sensor ATEX - 671V62K40-10- N.O./N.O., 10m cable
Safety sensor ATEX - 671V62K40-10- N.O./N.O., 10m cable
  • Product details
  • Technical Data

Safety sensor ATEX - 671V62K40-10- N.O./N.O., 10m cable

per item €555.39

available (5 pcs.), ships within 1-3 days

Quantity Price
from 25 pcs. €499.85 - 10 %
from 50 pcs. €444.31 - 20 %
from 100 pcs. €388.77 - 30 %

Ex-Marking: Nach RL 2014/34/EU ExII 1G Ex ia IIC T6/T5 Ga ExII 1D Ex ia IIIC IP68 T105°C Da

Choose variant:

Create offer

available (5 pcs.), ships within 1-3 days

Country of origin D
Item weight 0.8 kg
Customs tariff number 85365019
Technical Data
671271I40-5
€492.96
671271IU012-5
€450.24
671271K40-10
€555.36
671271KU012-5
€471.57
671271MU0-10
€474.42
671271MU0-5
€433.32
671271NU0-10
€495.72
671271NU0-5
€454.53
671V62I40-5
€492.93
671V62K40-10
€555.39
671V62KU012-10
€512.70
671V62MU0-10
€474.42
671V62N40-10
€538.26
671V62NU0-10
€495.72
671V62NU0-5
€454.53
Version dust: EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 1D Ex ia IIIC IP68 T 200 105°C Da EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation: front front front front front front front front front front front front front front front
Contact form: NO/NC NO/NC NO/NC NO/NO NO/NC NO/NC NO/NC NO/NC NO/NO NO/NO NO/NC NO/NO NO/NO NO/NO NO/NO
Effective internal capacitance (Ci): 2 nF 2 nF 2 nF 2 nF - - - - 2 nF 2 nF 2 nF - - - -
Effective internal inductance (Li): 10 µH 10 µH 10 µH 10 µH - - - - 10 µH 10 µH 10 µH - - - -
Max. input voltage Ui (i): 24 V AC/DC 24 V AC/DC 24 V AC/DC 0 V AC/DC - - - - 24 V AC/DC 24 V AC/DC 24 V AC/DC - - - -
Pollution degree: 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
Rated voltage Un (mb): - - - - 24 V AC/DC 24 V AC/DC 24 V AC/DC 24 V AC/DC - - - 24 V AC/DC 24 V AC/DC 24 V AC/DC 24 V AC/DC
Series resistor: 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm 22 Ohm
Switching frequency: 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz 5 Hz
Switching principle: magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic
Technology: Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified): 23 mm 23 mm 23 mm 20 mm 23 mm 23 mm 23 mm 23 mm 20 mm 20 mm 23 mm 20 mm 20 mm 20 mm 20 mm
Assured switch-off distance (Sar) with actuator (standard): 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm
Assured switching distance (Sao) with actuator (amplified): 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm
Assured switching distance (Sao) with actuator (standard): 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm 4 mm
B10d acc. to EN ISO 13849-1: 20000000 20000000 20000000 20000000 20000000 20000000 20000000 20000000 4000000 20000000 20000000 20000000 20000000 20000000 20000000
Coding acc. to EN ISO 14119: Low Low Low Low Low Low Low Low Low Low Low Low Low Low Low
Minimum switching distance (So min) with actuator (amplified): 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm
Minimum switching distance (So min) with actuator (standard): 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm
Mission time in years: 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a
Structure acc. to EN ISO 13849-1: Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel Two-channel
Type acc. to EN ISO 14119: 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Mechanical data
Detent present:
Dimensions: M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm M30 x 53 mm
Earth terminal:
Housing design: cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical cylindrical
Minimum installation distance (between two sensors): 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm
Material information
Cable material: PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
Housing colour: silber silber silber silber silber silber silber silber silber silber silber silber silber silber silber
Housing material: Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl
Nut material: Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA): T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C - - - - T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C - - - -
Ambient temperature range Ta, (Ii total: 60 ... 150 mA): T6: -25°C..+50° T5:T105°C: -25°C..+70°C T6: -25°C..+50° T5:T105°C: -25°C..+70°C T6: -25°C..+50° T5:T105°C: -25°C..+70°C T6: -25°C..+50° T5:T105°C: -25°C..+70°C - - - - T6: -25°C..+50° T5:T105°C: -25°C..+70°C T6: -25°C..+50° T5:T105°C: -25°C..+70°C T6: -25°C..+50° T5:T105°C: -25°C..+70°C - - - -
Ambient temperature range Ta, (In total: 0 ... 60 mA): - - - - T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C - - - T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA): - - - - T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C - - - T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature: 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C
Min. storage temperature: -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C
Protection class: IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar IP68 10bar
Shock resistance (Norm): 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms 30g / 11ms
Vibration resistance (Norm): 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz
Installation
Mounting type: Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut Fastening nut
Thread: M30 M30 M30 M30 M30 M30 M30 M30 M30 M30 M30 M30 M30 M30 M30
Connection
Cable colour: grau schwarz grau schwarz schwarz schwarz schwarz schwarz grau grau schwarz schwarz grau schwarz schwarz
Cable length: 5 m 5 m 10 m 5 m 10 m 5 m 10 m 5 m 5 m 10 m 10 m 10 m 10 m 10 m 5 m
Cable type: LIYCYW Y - UL 2517 LIYCYW Y - UL 2517 Y - UL 2517 Y - UL 2517 Y - UL 2517 Y - UL 2517 LIYCYW LIYCYW Y - UL 2517 Y - UL 2517 LIYCYW Y - UL 2517 Y - UL 2517
671271I40-5
€492.96
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
5 m
Cable type:
LIYCYW
671271IU012-5
€450.24
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271K40-10
€555.36
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671271KU012-5
€471.57
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
0 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271MU0-10
€474.42
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671271MU0-5
€433.32
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671271NU0-10
€495.72
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671271NU0-5
€454.53
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517
671V62I40-5
€492.93
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
4000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
5 m
Cable type:
LIYCYW
671V62K40-10
€555.39
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671V62KU012-10
€512.70
Version dust:
EX II 1D Ex ia IIIC IP68 T 200 105°C Da
Electrical data
Actuation:
front
Contact form:
NO/NC
Effective internal capacitance (Ci):
2 nF
Effective internal inductance (Li):
10 µH
Max. input voltage Ui (i):
24 V AC/DC
Pollution degree:
3
Rated voltage Un (mb):
-
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
23 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
T6: -25°C..+50° T5:T105°C: -25°C..+70°C
Ambient temperature range Ta, (In total: 0 ... 60 mA):
-
Ambient temperature range Ta, (In total: 60 ... 150 mA):
-
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62MU0-10
€474.42
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62N40-10
€538.26
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
grau
Cable length:
10 m
Cable type:
LIYCYW
671V62NU0-10
€495.72
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
10 m
Cable type:
Y - UL 2517
671V62NU0-5
€454.53
Version dust:
EX II 2D Ex mb IIIC IP68 T105°C Db
Electrical data
Actuation:
front
Contact form:
NO/NO
Effective internal capacitance (Ci):
-
Effective internal inductance (Li):
-
Max. input voltage Ui (i):
-
Pollution degree:
3
Rated voltage Un (mb):
24 V AC/DC
Series resistor:
22 Ohm
Switching frequency:
5 Hz
Switching principle:
magnetic
Technology:
Reed
Safety-related characteristics
Assured switch-off distance (Sar) with actuator (amplified):
20 mm
Assured switch-off distance (Sar) with actuator (standard):
16 mm
Assured switching distance (Sao) with actuator (amplified):
7 mm
Assured switching distance (Sao) with actuator (standard):
4 mm
B10d acc. to EN ISO 13849-1:
20000000
Coding acc. to EN ISO 14119:
Low
Minimum switching distance (So min) with actuator (amplified):
3 mm
Minimum switching distance (So min) with actuator (standard):
0.5 mm
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
Type acc. to EN ISO 14119:
4
Mechanical data
Detent present:
Dimensions:
M30 x 53 mm
Earth terminal:
Housing design:
cylindrical
Minimum installation distance (between two sensors):
50 mm
Material information
Cable material:
PVC
Housing colour:
silber
Housing material:
Edelstahl
Nut material:
Edelstahl
Environmental conditions
Ambient temperature range Ta, (Ii total: 0 ... 60 mA):
-
Ambient temperature range Ta, (Ii total: 60 ... 150 mA):
-
Ambient temperature range Ta, (In total: 0 ... 60 mA):
T6: -25°C..+70°C T5:T105°C: -25°C..+75°C
Ambient temperature range Ta, (In total: 60 ... 150 mA):
T6: -25°C..+50°C T5:T105°C: -25°C..+70°C
Max. storage temperature:
75 °C
Min. storage temperature:
-25 °C
Protection class:
IP68 10bar
Shock resistance (Norm):
30g / 11ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
Fastening nut
Thread:
M30
Connection
Cable colour:
schwarz
Cable length:
5 m
Cable type:
Y - UL 2517

Documents and Downloads

Instructions
Instruction for use 1
1.8 MB
download
Instruction for use 2
1.6 MB
download
Instruction for use 3
1.6 MB
download