Safety sensor - 117511E1 - with built-in relay | elostore
Safety sensor - 117511E1 - with built-in relay
article 117.1
Safety sensor - 117511E1 - with built-in relay
  • Product details
  • Technical Data

Safety sensor - 117511E1 - with built-in relay

per item €296.76

out of stock, deliverable in 60 working days

Quantity Price
from 10 pcs. €267.08 - 10 %
from 25 pcs. €237.41 - 20 %
from 50 pcs. €207.73 - 30 %

Choose variant:

Create offer

out of stock, deliverable in 60 working days

Product information
Country of origin D
Item weight 0.4 kg
Customs tariff number 85365019
The combination of safety sensor and safety control electronics in one housing, saves a great deal of space since no additional safety control device is necessary in the switch cabinet. This is a space-​saving and cost effective solution for guard door or bonnet monitoring in compact machines or retrofitting. An additional evaluation unit in the control cabinet is no longer required.
Features
  • Sensor and safety evaluation unit in one housing
  • Up to PL e/ SIL 3 (operation with direct load)
  • Operating voltage 24 V AC/DC or 230 V AC
  • Diagnosis LED
  • High protection class IP67 due to contactless, magnetic sensor actuation
  • Especially suitable for smaller machines
  • Loads up to 750VA/90W directly switchable
Downloads "Safety sensor - 117511E1 - with built-in relay"
Technical Data
117511E1
€296.76
117514E1
€318.48
117531H1
€432.33
117611E1
€296.76
117614E1
€318.48
117631H1
€432.33
117711E1
€296.76
117714E1
€318.48
Electrical data
Actuation: left side left side left side front front front top top
Assured switch-off distance (Sar): 21 mm 21 mm 21 mm 21 mm 21 mm 21 mm 21 mm 21 mm
Assured switching distance (Sao): 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm 3 mm
Current consumption: 60 mA 100 mA 100 mA 60 mA 100 mA 100 mA 60 mA 100 mA
EDM/start input:
Fuse control output: 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast
Fuse operating voltage: 0,5A fast 0,5A fast 0,5A fast 0,5A fast 0,5A fast 0,5A fast 0,5A fast 0,5A fast
Fuse safety output: 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast 3A fast
LED display: single-coloured single-coloured single-coloured single-coloured single-coloured single-coloured single-coloured single-coloured
Max no operating cycles at 0.5A switching current (ohmic load): 1000000 1000000 700000 1000000 1000000 700000 1000000 1000000
Max no operating cycles at 2.5A switching current (ohmic load): 230000 230000 25000 230000 230000 25000 230000 230000
Max. switching current at control output: 3 A 3 A 3 A 3 A 3 A 3 A 3 A 3 A
Max. switching current at safety output: 3 A 3 A 3 A 3 A 3 A 3 A 3 A 3 A
Max. switching power at control output: 90 W 90 W 90 W 90 W 90 W 90 W 90 W 90 W
Max. switching power at control output: 750 VA 750 VA 90 VA 750 VA 750 VA 90 VA 750 VA 750 VA
Max. switching power at safety output: 750 VA 750 VA 90 VA 750 VA 750 VA 90 VA 750 VA 750 VA
Max. switching power at safety output: 90 W 90 W 90 W 90 W 90 W 90 W 90 W 90 W
Max. switching voltage at control output: 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC
Max. switching voltage at control output: 250 V AC 250 V AC 30 V AC 250 V AC 250 V AC 30 V AC 250 V AC 250 V AC
Max. switching voltage at safety output: 250 V AC 250 V AC 30 V AC 250 V AC 250 V AC 30 V AC 250 V AC 250 V AC
Max. switching voltage at safety output: 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC 30 V DC
Min. switching current at control output: 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A 0.01 A
Min. switching current at safety output: 0.1 A 0.1 A 0.01 A 0.1 A 0.1 A 0.01 A 0.1 A 0.1 A
Min. switching power at control output: 0.12 VA 0.12 VA 3 VA 0.12 VA 0.12 VA 3 VA 0.12 VA 0.12 VA
Min. switching power at control output: 0.12 W 0.12 W 3 W 0.12 W 0.12 W 3 W 0.12 W 0.12 W
Min. switching power at safety output: 0.5 W 0.5 W 3 W 0.5 W 0.5 W 3 W 0.5 W 0.5 W
Min. switching power at safety output: - - 3 VA - - 3 VA - -
Min. switching voltage at control output: 12 V DC 12 V DC 10 V DC 12 V DC 12 V DC 10 V DC 12 V DC 12 V DC
Min. switching voltage at control output: 12 V AC 12 V AC 10 V AC 12 V AC 12 V AC 10 V AC 12 V AC 12 V AC
Min. switching voltage at safety output: 5 V DC 5 V DC 10 V DC 5 V DC 5 V DC 10 V DC 5 V DC 5 V DC
Min. switching voltage at safety output: - - 10 V AC - - 10 V AC - -
Minimum switching distance (S0 min): 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm 0.5 mm
Number of relay control outputs: 1 1 1 1 1 1 1 1
Number of relay safety outputs: 1 1 1 1 1 1 1 1
Operating voltage max.: 26.4 V AC 253 V AC 26.4 V AC 26.4 V AC 253 V AC 26.4 V AC 26.4 V AC 253 V AC
Operating voltage max.: 26.4 V DC - 26.4 V DC 26.4 V DC - 26.4 V DC 26.4 V DC -
Operating voltage min.: 21.6 V DC - 21.6 V DC 21.6 V DC - 21.6 V DC 21.6 V DC -
Operating voltage min.: 21.6 V AC 207 V AC 21.6 V AC 21.6 V AC 207 V AC 21.6 V AC 21.6 V AC 207 V AC
Overvoltage category: III III III III III III III III
Pollution degree: 2 2 2 2 2 2 2 2
Power consumption: 1.5 VA 23 VA 2.4 VA 1.5 VA 23 VA 2.4 VA 1.5 VA 23 VA
Power consumption: 1.5 W - 2.4 W 1.5 W - 2.4 W 1.5 W -
Protection class: III III III III III III III III
Readiness delay (tv): 350 ms 350 ms 350 ms 350 ms 350 ms 350 ms 350 ms 350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle: magnetic magnetic magnetic magnetic magnetic magnetic magnetic magnetic
Technology: Reed Reed Reed Reed Reed Reed Reed Reed
Utilization category: AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13 AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1: 3 3 4 3 3 4 3 3
Coding acc. to EN ISO 14119: Low Low Low Low Low Low Low Low
Mission time in years: 20 a 20 a 20 a 20 a 20 a 20 a 20 a 20 a
PL acc. to EN ISO 13849-1: d d e d d e d d
Type acc. to EN ISO 14119: 4 4 4 4 4 4 4 4
Mechanical data
Actuation frequency: 18000 1/h 18000 1/h 18000 1/h 18000 1/h 18000 1/h 18000 1/h 18000 1/h 18000 1/h
Dimensions: 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm 120 x 40 x 40 mm
Free zone: 25 mm 25 mm 25 mm 25 mm 25 mm 25 mm 25 mm 25 mm
Housing design: rectangular rectangular rectangular rectangular rectangular rectangular rectangular rectangular
Minimum installation distance (between two sensors): 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm 50 mm
Operating speed max.: 0.1 m/min 0.1 m/min 0.1 m/min 0.1 m/min 0.1 m/min 0.1 m/min 0.1 m/min 0.1 m/min
cannot be mounted flush:
Material information
Cable material: TPE TPE - TPE TPE - TPE TPE
Housing colour: schwarz schwarz schwarz schwarz schwarz schwarz schwarz schwarz
Housing material: PBT PBT PBT PBT PBT PBT PBT PBT
Environmental conditions
Air pressure: 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa 860 - 1060 hPa
Continuous shock resistance (Norm): 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms 10 g / 16 ms
Delta tmax: 0.5 °C/min 0.5 °C/min 0.5 °C/min 0.5 °C/min 0.5 °C/min 0.5 °C/min 0.5 °C/min 0.5 °C/min
Max. cable temperature range, fixed installation: 55 °C 55 °C - 55 °C 55 °C - 55 °C 55 °C
Max. cable temperature range, moving: 55 °C 55 °C - 55 °C 55 °C - 55 °C 55 °C
Max. operating temperature: 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Max. storage temperature: 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Min. cable temperature range, fixed installation: -25 °C -25 °C - -25 °C -25 °C - -25 °C -25 °C
Min. cable temperature range, moving: -25 °C -25 °C - -25 °C -25 °C - -25 °C -25 °C
Min. storage temperature: -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C
Operating temperature min.: -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C -25 °C
Protection class: IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Protection class, connector: - - IP67 DIN EN 60529 - - IP67 DIN EN 60529 - -
Relative humidity: 5 - 85 % 5 - 85 % 5 - 85 % 5 - 85 % 5 - 85 % 5 - 85 % 5 - 85 % 5 - 85 %
Shock resistance (Norm): 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms 30 g / 11 ms
Vibration resistance (Norm): 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz 10 ... 55 Hz
Installation
Mounting type: screwed screwed screwed screwed screwed screwed screwed screwed
Weight: 500 g 500 g 500 g 500 g 500 g 500 g 500 g 500 g
Connection
Cable colour: silbergrau silbergrau - silbergrau silbergrau - silbergrau silbergrau
Cable length: 1 m 1 m - 1 m 1 m - 1 m 1 m
Connector type: - - M12x1 - 5 polig - - M12x1 - 5 polig - -
Number of strands: 5 5 - 5 5 - 5 5
Wire cross section: 0.75 mm^2 0.75 mm^2 - 0.75 mm^2 0.75 mm^2 - 0.75 mm^2 0.75 mm^2
Approvals
CE label:
Certified in accordance with: EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2 EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators: 30427102 30427102 30427102 30427102 30427102 30427102 30427102 30427102
117511E1
€296.76
Electrical data
Actuation:
left side
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
60 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
26.4 V AC
Operating voltage max.:
26.4 V DC
Operating voltage min.:
21.6 V DC
Operating voltage min.:
21.6 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
1.5 VA
Power consumption:
1.5 W
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117514E1
€318.48
Electrical data
Actuation:
left side
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
100 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
253 V AC
Operating voltage max.:
-
Operating voltage min.:
-
Operating voltage min.:
207 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
23 VA
Power consumption:
-
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117531H1
€432.33
Electrical data
Actuation:
left side
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
100 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
700000
Max no operating cycles at 2.5A switching current (ohmic load):
25000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
90 VA
Max. switching power at safety output:
90 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
30 V AC
Max. switching voltage at safety output:
30 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.01 A
Min. switching power at control output:
3 VA
Min. switching power at control output:
3 W
Min. switching power at safety output:
3 W
Min. switching power at safety output:
3 VA
Min. switching voltage at control output:
10 V DC
Min. switching voltage at control output:
10 V AC
Min. switching voltage at safety output:
10 V DC
Min. switching voltage at safety output:
10 V AC
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
26.4 V AC
Operating voltage max.:
26.4 V DC
Operating voltage min.:
21.6 V DC
Operating voltage min.:
21.6 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
2.4 VA
Power consumption:
2.4 W
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
e
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
-
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
-
Max. cable temperature range, moving:
-
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-
Min. cable temperature range, moving:
-
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
IP67 DIN EN 60529
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
-
Cable length:
-
Connector type:
M12x1 - 5 polig
Number of strands:
-
Wire cross section:
-
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117611E1
€296.76
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
60 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
26.4 V AC
Operating voltage max.:
26.4 V DC
Operating voltage min.:
21.6 V DC
Operating voltage min.:
21.6 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
1.5 VA
Power consumption:
1.5 W
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117614E1
€318.48
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
100 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
253 V AC
Operating voltage max.:
-
Operating voltage min.:
-
Operating voltage min.:
207 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
23 VA
Power consumption:
-
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117631H1
€432.33
Electrical data
Actuation:
front
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
100 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
700000
Max no operating cycles at 2.5A switching current (ohmic load):
25000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
90 VA
Max. switching power at safety output:
90 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
30 V AC
Max. switching voltage at safety output:
30 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.01 A
Min. switching power at control output:
3 VA
Min. switching power at control output:
3 W
Min. switching power at safety output:
3 W
Min. switching power at safety output:
3 VA
Min. switching voltage at control output:
10 V DC
Min. switching voltage at control output:
10 V AC
Min. switching voltage at safety output:
10 V DC
Min. switching voltage at safety output:
10 V AC
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
26.4 V AC
Operating voltage max.:
26.4 V DC
Operating voltage min.:
21.6 V DC
Operating voltage min.:
21.6 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
2.4 VA
Power consumption:
2.4 W
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
e
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
-
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
-
Max. cable temperature range, moving:
-
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-
Min. cable temperature range, moving:
-
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
IP67 DIN EN 60529
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
-
Cable length:
-
Connector type:
M12x1 - 5 polig
Number of strands:
-
Wire cross section:
-
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117711E1
€296.76
Electrical data
Actuation:
top
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
60 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
26.4 V AC
Operating voltage max.:
26.4 V DC
Operating voltage min.:
21.6 V DC
Operating voltage min.:
21.6 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
1.5 VA
Power consumption:
1.5 W
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102
117714E1
€318.48
Electrical data
Actuation:
top
Assured switch-off distance (Sar):
21 mm
Assured switching distance (Sao):
3 mm
Current consumption:
100 mA
EDM/start input:
Fuse control output:
3A fast
Fuse operating voltage:
0,5A fast
Fuse safety output:
3A fast
LED display:
single-coloured
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching current at control output:
3 A
Max. switching current at safety output:
3 A
Max. switching power at control output:
90 W
Max. switching power at control output:
750 VA
Max. switching power at safety output:
750 VA
Max. switching power at safety output:
90 W
Max. switching voltage at control output:
30 V DC
Max. switching voltage at control output:
250 V AC
Max. switching voltage at safety output:
250 V AC
Max. switching voltage at safety output:
30 V DC
Min. switching current at control output:
0.01 A
Min. switching current at safety output:
0.1 A
Min. switching power at control output:
0.12 VA
Min. switching power at control output:
0.12 W
Min. switching power at safety output:
0.5 W
Min. switching power at safety output:
-
Min. switching voltage at control output:
12 V DC
Min. switching voltage at control output:
12 V AC
Min. switching voltage at safety output:
5 V DC
Min. switching voltage at safety output:
-
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Number of relay safety outputs:
1
Operating voltage max.:
253 V AC
Operating voltage max.:
-
Operating voltage min.:
-
Operating voltage min.:
207 V AC
Overvoltage category:
III
Pollution degree:
2
Power consumption:
23 VA
Power consumption:
-
Protection class:
III
Readiness delay (tv):
350 ms
Stop category 0 (STO) nach IEC 61800-5-2:
Stop category 1 (SS1) nach IEC 61800-5-2:
Switching principle:
magnetic
Technology:
Reed
Utilization category:
AC-15 / DC-13
Safety-related characteristics
Category acc. to EN ISO 13849-1:
3
Coding acc. to EN ISO 14119:
Low
Mission time in years:
20 a
PL acc. to EN ISO 13849-1:
d
Type acc. to EN ISO 14119:
4
Mechanical data
Actuation frequency:
18000 1/h
Dimensions:
120 x 40 x 40 mm
Free zone:
25 mm
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Operating speed max.:
0.1 m/min
cannot be mounted flush:
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Air pressure:
860 - 1060 hPa
Continuous shock resistance (Norm):
10 g / 16 ms
Delta tmax:
0.5 °C/min
Max. cable temperature range, fixed installation:
55 °C
Max. cable temperature range, moving:
55 °C
Max. operating temperature:
55 °C
Max. storage temperature:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-25 °C
Min. storage temperature:
-25 °C
Operating temperature min.:
-25 °C
Protection class:
IP67 DIN EN 60529
Protection class, connector:
-
Relative humidity:
5 - 85 %
Shock resistance (Norm):
30 g / 11 ms
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Mounting type:
screwed
Weight:
500 g
Connection
Cable colour:
silbergrau
Cable length:
1 m
Connector type:
-
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
Operating data
Possible actuators:
30427102