Safety sensor - 117711E1-7 - with built-in relay, 7m cable
per item €349.11
available (12 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 10 pcs. | €314.20 - 10 % |
from 25 pcs. | €279.29 - 20 % |
from 50 pcs. | €244.38 - 30 % |
Product number: 117711E1-7
Product information
Country of origin | D |
---|---|
Item weight | 0.85 kg |
Customs tariff number | 85365019 |
Features
-
Sensor and safety evaluation unit in one housing
-
Up to PL e/ SIL 3 (operation with direct load)
-
Operating voltage 24 V AC/DC or 230 V AC
-
Diagnosis LED
-
High protection class IP67 due to contactless, magnetic sensor actuation
-
Especially suitable for smaller machines
-
Loads up to 750VA/90W directly switchable
Downloads "Safety sensor - 117711E1-7 - with built-in relay, 7m cable"
Technical Data
117711E1-7
€349.11
|
||
Electrical data
|
||
Min. switching current at safety output: | 0.1 A | |
---|---|---|
Utilization category: | AC-15 / DC-13 | |
Switching principle: | magnetic | |
Min. switching voltage at safety output: | 5 V DC | |
Protection class: | III | |
Number of relay safety outputs: | 1 | |
Min. switching voltage at control output: | 12 V DC | |
Pollution degree: | 2 | |
Min. switching current at control output: | 0.01 A | |
Max. switching voltage at control output: | 30 V DC | |
LED display: | single-coloured | |
Max. switching power at safety output: | 750 VA | |
Readiness delay (tv): | 350 ms | |
Max. switching voltage at safety output: | 250 V AC | |
Operating voltage max.: | 26.4 V AC | |
Max. switching current at safety output: | 3 A | |
Overvoltage category: | III | |
Fuse safety output: | 3A fast | |
Max. switching power at control output: | 90 W | |
Assured switch-off distance (Sar): | 21 mm | |
Actuation: | top | |
Min. switching power at control output: | 0.12 VA | |
Power consumption: | 1.5 VA | |
Technology: | Reed | |
Current consumption: | 60 mA | |
Max. switching voltage at control output: | 250 V AC | |
Stop category 0 (STO) nach IEC 61800-5-2: | ||
Max. switching voltage at safety output: | 30 V DC | |
Min. switching power at safety output: | 0.5 W | |
Max no operating cycles at 0.5A switching current (ohmic load): | 1000000 | |
Fuse control output: | 3A fast | |
EDM/start input: | ||
Max. switching current at control output: | 3 A | |
Max. switching power at control output: | 750 VA | |
Power consumption: | 1.5 W | |
Operating voltage min.: | 21.6 V DC | |
Stop category 1 (SS1) nach IEC 61800-5-2: | ||
Operating voltage min.: | 21.6 V AC | |
Min. switching power at control output: | 0.12 W | |
Max no operating cycles at 2.5A switching current (ohmic load): | 230000 | |
Max. switching power at safety output: | 90 W | |
Min. switching voltage at control output: | 12 V AC | |
Assured switching distance (Sao): | 3 mm | |
Operating voltage max.: | 26.4 V DC | |
Minimum switching distance (S0 min): | 0.5 mm | |
Number of relay control outputs: | 1 | |
Fuse operating voltage: | 0,5A fast | |
Safety-related characteristics
|
||
PL acc. to EN ISO 13849-1: | d | |
Mission time in years: | 20 a | |
Category acc. to EN ISO 13849-1: | 3 | |
Type acc. to EN ISO 14119: | 4 | |
Coding acc. to EN ISO 14119: | Low | |
Mechanical data
|
||
Dimensions: | 120 x 40 x 40 mm | |
cannot be mounted flush: | ||
Actuation frequency: | 18000 1/h | |
Operating speed max.: | 0.1 m/min | |
Housing design: | rectangular | |
Minimum installation distance (between two sensors): | 50 mm | |
Free zone: | 25 mm | |
Material information
|
||
Cable material: | TPE | |
Housing colour: | schwarz | |
Housing material: | PBT | |
Environmental conditions
|
||
Max. cable temperature range, moving: | 55 °C | |
Min. cable temperature range, fixed installation: | -25 °C | |
Max. operating temperature: | 55 °C | |
Protection class: | IP67 DIN EN 60529 | |
Min. storage temperature: | -25 °C | |
Continuous shock resistance (Norm): | 10 g / 16 ms | |
Operating temperature min.: | -25 °C | |
Shock resistance (Norm): | 30 g / 11 ms | |
Air pressure: | 860 - 1060 hPa | |
Max. cable temperature range, fixed installation: | 55 °C | |
Max. storage temperature: | 55 °C | |
Delta tmax: | 0.5 °C/min | |
Relative humidity: | 5 - 85 % | |
Min. cable temperature range, moving: | -25 °C | |
Vibration resistance (Norm): | 10 ... 55 Hz | |
Installation
|
||
Weight: | 500 g | |
Mounting type: | screwed | |
Connection
|
||
Cable colour: | silbergrau | |
Cable length: | 1 m | |
Number of strands: | 5 | |
Wire cross section: | 0.75 mm^2 | |
Approvals
|
||
Certified in accordance with: | EN ISO 13849-1 UL 508 / CSA 22.2 | |
CE label: | ||
Operating data
|
||
Possible actuators: | 30427102 |
117711E1-7
€349.11
Electrical data
Min. switching current at safety output:
0.1 A
Utilization category:
AC-15 / DC-13
Switching principle:
magnetic
Min. switching voltage at safety output:
5 V DC
Protection class:
III
Number of relay safety outputs:
1
Min. switching voltage at control output:
12 V DC
Pollution degree:
2
Min. switching current at control output:
0.01 A
Max. switching voltage at control output:
30 V DC
LED display:
single-coloured
Max. switching power at safety output:
750 VA
Readiness delay (tv):
350 ms
Max. switching voltage at safety output:
250 V AC
Operating voltage max.:
26.4 V AC
Max. switching current at safety output:
3 A
Overvoltage category:
III
Fuse safety output:
3A fast
Max. switching power at control output:
90 W
Assured switch-off distance (Sar):
21 mm
Actuation:
top
Min. switching power at control output:
0.12 VA
Power consumption:
1.5 VA
Technology:
Reed
Current consumption:
60 mA
Max. switching voltage at control output:
250 V AC
Stop category 0 (STO) nach IEC 61800-5-2:
Max. switching voltage at safety output:
30 V DC
Min. switching power at safety output:
0.5 W
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Fuse control output:
3A fast
EDM/start input:
Max. switching current at control output:
3 A
Max. switching power at control output:
750 VA
Power consumption:
1.5 W
Operating voltage min.:
21.6 V DC
Stop category 1 (SS1) nach IEC 61800-5-2:
Operating voltage min.:
21.6 V AC
Min. switching power at control output:
0.12 W
Max no operating cycles at 2.5A switching current (ohmic load):
230000
Max. switching power at safety output:
90 W
Min. switching voltage at control output:
12 V AC
Assured switching distance (Sao):
3 mm
Operating voltage max.:
26.4 V DC
Minimum switching distance (S0 min):
0.5 mm
Number of relay control outputs:
1
Fuse operating voltage:
0,5A fast
Safety-related characteristics
PL acc. to EN ISO 13849-1:
d
Mission time in years:
20 a
Category acc. to EN ISO 13849-1:
3
Type acc. to EN ISO 14119:
4
Coding acc. to EN ISO 14119:
Low
Mechanical data
Dimensions:
120 x 40 x 40 mm
cannot be mounted flush:
Actuation frequency:
18000 1/h
Operating speed max.:
0.1 m/min
Housing design:
rectangular
Minimum installation distance (between two sensors):
50 mm
Free zone:
25 mm
Material information
Cable material:
TPE
Housing colour:
schwarz
Housing material:
PBT
Environmental conditions
Max. cable temperature range, moving:
55 °C
Min. cable temperature range, fixed installation:
-25 °C
Max. operating temperature:
55 °C
Protection class:
IP67 DIN EN 60529
Min. storage temperature:
-25 °C
Continuous shock resistance (Norm):
10 g / 16 ms
Operating temperature min.:
-25 °C
Shock resistance (Norm):
30 g / 11 ms
Air pressure:
860 - 1060 hPa
Max. cable temperature range, fixed installation:
55 °C
Max. storage temperature:
55 °C
Delta tmax:
0.5 °C/min
Relative humidity:
5 - 85 %
Min. cable temperature range, moving:
-25 °C
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Weight:
500 g
Mounting type:
screwed
Connection
Cable colour:
silbergrau
Cable length:
1 m
Number of strands:
5
Wire cross section:
0.75 mm^2
Approvals
Certified in accordance with:
EN ISO 13849-1 UL 508 / CSA 22.2
CE label:
Operating data
Possible actuators:
30427102
Documents and Downloads
Instructions
Data sheets