Safe signal evaluation - eloFlex - 471EFR3E12K0144 - (without terminals)
Part number:
Art. -No.
471EFR3E12K0144
per item €803.85
available (1 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 10 pcs. | €723.47 - 10 % |
from 25 pcs. | €643.08 - 20 % |
from 50 pcs. | €562.70 - 30 % |
Country of origin | Germany |
---|---|
Item weight | 0.315 kg |
Customs tariff number | 85365080 |
Technical Data
471EFR3E12K0144
€803.85
|
||
Electrical data
|
||
Max. switching power at control output: | 2.64 W | |
---|---|---|
Number of configurable relay safety outputs: | 2 | |
Max no operating cycles at 0.5A switching current (ohmic load): | 3000000 | |
Max. switching power at safety output: | 750 VA | |
Number of electronic control outputs: | 4 | |
Max. switching voltage at safety output: | 250 V AC | |
Max. switching current at safety output: | 3 A | |
Max. switching voltage at control output: | 26.4 V DC | |
LED display: | two-coloured | |
Fuse safety output: | Yes | |
Fuse operating voltage: | 1A fast | |
Max. switching voltage at safety output: | 30 V DC | |
Start function: | Depending on the configuration | |
Operating voltage min.: | 21.6 V DC | |
EDM/start input: | ||
Max. switching power at safety output: | 90 W | |
Max. switching current at control output: | 0.1 A | |
Operating voltage max.: | 26.4 V DC | |
Max no operating cycles at 3A switching current (ohmic load): | 280000 | |
Safety-related characteristics
|
||
Category acc. to EN ISO 13849-1: | 4 | |
PL acc. to EN ISO 13849-1: | e | |
SIL acc. to IEC 61508: | 3 | |
SIL CL acc. to IEC 62061: | 3 | |
Hardware fault tolerance (HFT) according to IEC 61508: | 1 | |
PFHD according to IEC 61508: | 3,28x10^-9 1/h | |
Material information
|
||
Housing colour: | schwarz | |
Housing material: | PA, PC | |
Environmental conditions
|
||
Relative humidity: | 5 ... 85 % | |
Max. operating temperature: | 55 °C | |
Operating temperature min.: | -15 °C | |
Min. storage temperature: | -25 °C | |
Max. storage temperature: | 70 °C | |
Delta tmax: | 0.5 °C/min | |
Air pressure: | 860 ... 1060 hPa | |
Installation
|
||
Mounting type: | Mounting rail | |
Connection
|
||
Double terminals: | Optional | |
Spring-type terminals: | Optional | |
Screw terminals: | Optional | |
Pluggable connection terminals: |
471EFR3E12K0144
€803.85
Electrical data
Max. switching power at control output:
2.64 W
Number of configurable relay safety outputs:
2
Max no operating cycles at 0.5A switching current (ohmic load):
3000000
Max. switching power at safety output:
750 VA
Number of electronic control outputs:
4
Max. switching voltage at safety output:
250 V AC
Max. switching current at safety output:
3 A
Max. switching voltage at control output:
26.4 V DC
LED display:
two-coloured
Fuse safety output:
Yes
Fuse operating voltage:
1A fast
Max. switching voltage at safety output:
30 V DC
Start function:
Depending on the configuration
Operating voltage min.:
21.6 V DC
EDM/start input:
Max. switching power at safety output:
90 W
Max. switching current at control output:
0.1 A
Operating voltage max.:
26.4 V DC
Max no operating cycles at 3A switching current (ohmic load):
280000
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
PL acc. to EN ISO 13849-1:
e
SIL acc. to IEC 61508:
3
SIL CL acc. to IEC 62061:
3
Hardware fault tolerance (HFT) according to IEC 61508:
1
PFHD according to IEC 61508:
3,28x10^-9 1/h
Material information
Housing colour:
schwarz
Housing material:
PA, PC
Environmental conditions
Relative humidity:
5 ... 85 %
Max. operating temperature:
55 °C
Operating temperature min.:
-15 °C
Min. storage temperature:
-25 °C
Max. storage temperature:
70 °C
Delta tmax:
0.5 °C/min
Air pressure:
860 ... 1060 hPa
Installation
Mounting type:
Mounting rail
Connection
Double terminals:
Optional
Spring-type terminals:
Optional
Screw terminals:
Optional
Pluggable connection terminals:
Documents and Downloads
Instructions