Safe signal evaluation - eloFlex - 471EFR2D14K0196 - (without terminals)
Part number:
Art. -No.
471EFR2D14K0196
per item €682.05
available (1 pcs.), ships within 1-3 days
| Quantity | Price |
|---|---|
| from 10 pcs. | €613.85 - 10 % |
| from 25 pcs. | €545.64 - 20 % |
| from 50 pcs. | €477.44 - 30 % |
| Country of origin | Germany |
|---|---|
| Item weight | 0.215 kg |
| Customs tariff number | 85365080 |
Technical Data
|
471EFR2D14K0196
€682.05
|
||
|
Electrical data
|
||
| Max. switching power at control output: | 2.64 W | |
|---|---|---|
| Number of configurable relay safety outputs: | 4 | |
| Max. switching power at safety output: | 750 VA | |
| Number of electronic control outputs: | 4 | |
| Max. switching voltage at safety output: | 250 V AC | |
| Max. switching current at safety output: | 3 A | |
| Max. switching voltage at control output: | 26.4 V DC | |
| LED display: | two-coloured | |
| Fuse safety output: | Yes | |
| Fuse operating voltage: | 1A fast | |
| Max. switching voltage at safety output: | 30 V DC | |
| Max no operating cycles at 0.5A switching current (ohmic load): | 1000000 | |
| Start function: | Depending on the configuration | |
| Operating voltage min.: | 21.6 V DC | |
| EDM/start input: | ||
| Max no operating cycles at 3A switching current (ohmic load): | 190000 | |
| Max. switching power at safety output: | 90 W | |
| Max. switching current at control output: | 0.1 A | |
| Operating voltage max.: | 26.4 V DC | |
|
Safety-related characteristics
|
||
| PL acc. to EN ISO 13849-1: | d | |
| PFHD according to IEC 61508: | 1,26x10^-8 1/h | |
| SIL CL acc. to IEC 62061: | 2 | |
| Hardware fault tolerance (HFT) according to IEC 61508: | 1 | |
| SIL acc. to IEC 61508: | 2 | |
| Category acc. to EN ISO 13849-1: | 3 | |
|
Material information
|
||
| Housing colour: | schwarz | |
| Housing material: | PA, PC | |
|
Environmental conditions
|
||
| Min. storage temperature: | -40 °C | |
| Relative humidity: | 5 ... 85 % | |
| Max. operating temperature: | 55 °C | |
| Operating temperature min.: | -15 °C | |
| Max. storage temperature: | 70 °C | |
| Delta tmax: | 0.5 °C/min | |
| Air pressure: | 860 ... 1060 hPa | |
|
Installation
|
||
| Mounting type: | Mounting rail | |
|
Connection
|
||
| Double terminals: | Optional | |
| Spring-type terminals: | Optional | |
| Screw terminals: | Optional | |
| Pluggable connection terminals: |
471EFR2D14K0196
€682.05
Electrical data
Max. switching power at control output:
2.64 W
Number of configurable relay safety outputs:
4
Max. switching power at safety output:
750 VA
Number of electronic control outputs:
4
Max. switching voltage at safety output:
250 V AC
Max. switching current at safety output:
3 A
Max. switching voltage at control output:
26.4 V DC
LED display:
two-coloured
Fuse safety output:
Yes
Fuse operating voltage:
1A fast
Max. switching voltage at safety output:
30 V DC
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Start function:
Depending on the configuration
Operating voltage min.:
21.6 V DC
EDM/start input:
Max no operating cycles at 3A switching current (ohmic load):
190000
Max. switching power at safety output:
90 W
Max. switching current at control output:
0.1 A
Operating voltage max.:
26.4 V DC
Safety-related characteristics
PL acc. to EN ISO 13849-1:
d
PFHD according to IEC 61508:
1,26x10^-8 1/h
SIL CL acc. to IEC 62061:
2
Hardware fault tolerance (HFT) according to IEC 61508:
1
SIL acc. to IEC 61508:
2
Category acc. to EN ISO 13849-1:
3
Material information
Housing colour:
schwarz
Housing material:
PA, PC
Environmental conditions
Min. storage temperature:
-40 °C
Relative humidity:
5 ... 85 %
Max. operating temperature:
55 °C
Operating temperature min.:
-15 °C
Max. storage temperature:
70 °C
Delta tmax:
0.5 °C/min
Air pressure:
860 ... 1060 hPa
Installation
Mounting type:
Mounting rail
Connection
Double terminals:
Optional
Spring-type terminals:
Optional
Screw terminals:
Optional
Pluggable connection terminals:
Documents and Downloads