Safe signal evaluation - eloFlex - 471EFR2D14K0059 - (without terminals)
Part number:
Art. -No.
471EFR2D14K0059
per item €682.05
available (4 pcs.), ships within 1-3 days
Quantity | Price |
---|---|
from 10 pcs. | €613.85 - 10 % |
from 25 pcs. | €545.64 - 20 % |
from 50 pcs. | €477.44 - 30 % |
Product information
Country of origin | Germany |
---|---|
Item weight | 0.333 kg |
Customs tariff number | 85365080 |
elobau safety relays reliably perform safety-related functions. They are the suitable solution for safety applications of varying complexity. All signals from safety sensors are safely monitored and comply with the requirements of the Machinery Directive 2006/42/EC.
Thereby eloFlex 471 EFR... are configurable safety evaluation units with 4 independent safety inputs (2-channel) and up to 4 safety outputs as well as 4 control outputs.
The internal logic links are already pre-configured.
ATTENTION: This product is sold WITHOUT standard clamps. These must be purchased separately (item no. 878598VPE4).
Features
-
- Realisation of up to 4 safety functions in one device variant (varies according to variant)
-
- demand-oriented number of safety outputs (relays) according to the requirements, enables an economic solution
-
- more functions with less space required in the control cabinet - this saves costs
-
- tamper-proof due to defined and validated configuration by elobau
-
- economical and safe due to clear identification of the configuration during maintenance, commissioning and service
-
- additional sensors can be connected via elobau interfaces for input expansion
Technical Data
471EFR2D14K0059
€682.05
|
||
Electrical data
|
||
Utilization category: | AC-15 / DC-13 | |
---|---|---|
Number of configurable relay safety outputs: | 4 | |
Max. switching power at safety output: | 750 VA | |
Number of electronic control outputs: | 4 | |
Current consumption: | 800 mA | |
Max. switching voltage at safety output: | 250 V AC | |
Max. switching current at safety output: | 3 A | |
Max. switching voltage at control output: | 26.4 V DC | |
LED display: | two-coloured | |
Overvoltage category: | II | |
Max. switching power at control output: | 2.4 W | |
Stop category 0 (STO) nach IEC 61800-5-2: | ||
Max. switching voltage at safety output: | 30 V DC | |
Number of redundant safety inputs: | 4 | |
Max no operating cycles at 0.5A switching current (ohmic load): | 1000000 | |
Start function: | Depending on the configuration | |
Operating voltage min.: | 21.6 V DC | |
Cross-short detection: | ||
Power consumption: | 19.2 W | |
Min. switching voltage at control output: | 21.6 V DC | |
EDM/start input: | ||
Operating time: | 3000 ms | |
Max no operating cycles at 3A switching current (ohmic load): | 190000 | |
Max. switching power at safety output: | 90 W | |
Max. switching current at control output: | 0.1 A | |
Contact form: | Abhängig von der Konfiguration | |
Operating voltage max.: | 26.4 V DC | |
Stop category 1 (SS1) nach IEC 61800-5-2: | ||
Safety-related characteristics
|
||
Operating life: | 20 Tm | |
PFHD according to IEC 61508: | 8,75x10^-8 1/h | |
PL acc. to EN ISO 13849-1: | d | |
SIL CL acc. to IEC 62061: | 2 | |
Hardware fault tolerance (HFT) according to IEC 61508: | 1 | |
SIL acc. to IEC 61508: | 2 | |
Category acc. to EN ISO 13849-1: | 3 | |
Mechanical data
|
||
Dimensions: | 130 x 45 x 120 mm (H/B/T) | |
Material information
|
||
Housing colour: | schwarz | |
Housing material: | PA, PC | |
Environmental conditions
|
||
Min. storage temperature: | -40 °C | |
Max. operating temperature: | 55 °C | |
Continuous shock resistance (Norm): | 10 g / 16 ms | |
Operating temperature min.: | -25 °C | |
Shock resistance (Norm): | 30 g / 11 ms | |
Air pressure: | 860 - 1060 hPa | |
Max. storage temperature: | 70 °C | |
Delta tmax: | 0.5 °C/min | |
Relative humidity: | 5 - 85 % | |
Protection class, installation space: | IP55 IEC60529 | |
Protection class: | IP30 IEC60529 | |
Vibration resistance (Norm): | 10 ... 55 Hz | |
Installation
|
||
Weight: | 400 g | |
Torque for connection terminals: | 0.5 N m | |
Mounting type: | Mounting rail | |
Connection
|
||
Max. connection cross section: | 2.5 mm^2 | |
Min. connection cross section: | 0.2 mm^2 | |
Double terminals: | Optional | |
Spring-type terminals: | ||
Screw terminals: | Optional | |
Pluggable connection terminals: | ||
Approvals
|
||
CE label: | ||
Certified in accordance with: | EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2 |
471EFR2D14K0059
€682.05
Electrical data
Utilization category:
AC-15 / DC-13
Number of configurable relay safety outputs:
4
Max. switching power at safety output:
750 VA
Number of electronic control outputs:
4
Current consumption:
800 mA
Max. switching voltage at safety output:
250 V AC
Max. switching current at safety output:
3 A
Max. switching voltage at control output:
26.4 V DC
LED display:
two-coloured
Overvoltage category:
II
Max. switching power at control output:
2.4 W
Stop category 0 (STO) nach IEC 61800-5-2:
Max. switching voltage at safety output:
30 V DC
Number of redundant safety inputs:
4
Max no operating cycles at 0.5A switching current (ohmic load):
1000000
Start function:
Depending on the configuration
Operating voltage min.:
21.6 V DC
Cross-short detection:
Power consumption:
19.2 W
Min. switching voltage at control output:
21.6 V DC
EDM/start input:
Operating time:
3000 ms
Max no operating cycles at 3A switching current (ohmic load):
190000
Max. switching power at safety output:
90 W
Max. switching current at control output:
0.1 A
Contact form:
Abhängig von der Konfiguration
Operating voltage max.:
26.4 V DC
Stop category 1 (SS1) nach IEC 61800-5-2:
Safety-related characteristics
Operating life:
20 Tm
PFHD according to IEC 61508:
8,75x10^-8 1/h
PL acc. to EN ISO 13849-1:
d
SIL CL acc. to IEC 62061:
2
Hardware fault tolerance (HFT) according to IEC 61508:
1
SIL acc. to IEC 61508:
2
Category acc. to EN ISO 13849-1:
3
Mechanical data
Dimensions:
130 x 45 x 120 mm (H/B/T)
Material information
Housing colour:
schwarz
Housing material:
PA, PC
Environmental conditions
Min. storage temperature:
-40 °C
Max. operating temperature:
55 °C
Continuous shock resistance (Norm):
10 g / 16 ms
Operating temperature min.:
-25 °C
Shock resistance (Norm):
30 g / 11 ms
Air pressure:
860 - 1060 hPa
Max. storage temperature:
70 °C
Delta tmax:
0.5 °C/min
Relative humidity:
5 - 85 %
Protection class, installation space:
IP55 IEC60529
Protection class:
IP30 IEC60529
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Weight:
400 g
Torque for connection terminals:
0.5 N m
Mounting type:
Mounting rail
Connection
Max. connection cross section:
2.5 mm^2
Min. connection cross section:
0.2 mm^2
Double terminals:
Optional
Spring-type terminals:
Screw terminals:
Optional
Pluggable connection terminals:
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
Documents and Downloads
Instructions