Safety sensor NO/NC-5mCab. 4-wire
Part number:
Art. -No.
17127118-5
Country of origin | D |
---|---|
Item weight | 0.001 kg |
Customs tariff number | 85365019 |
Technical Data
17127118-5
€96.00
|
||
Electrical data
|
||
Switching principle: | magnetic | |
---|---|---|
Protection class: | III | |
LED display: | No | |
Switching frequency: | 5 Hz | |
Max. switching power: | 3 W | |
Technology: | Reed | |
Assured switch-off distance (Sar): | 23 mm | |
Series resistor: | 22 Ohm | |
Actuation: | front | |
Pollution degree: | 3 | |
Assured switching distance (Sao): | 7 mm | |
Minimum switching distance (S0 min): | 3 mm | |
Min. switching voltage: | 19.2 V DC | |
Contact form: | NO/NC | |
Max. switching voltage: | 28.8 V DC | |
Safety-related characteristics
|
||
Mission time in years: | 20 a | |
Structure acc. to EN ISO 13849-1: | Two-channel | |
B10d acc. to EN ISO 13849-1: | 20000000 | |
Type acc. to EN ISO 14119: | 4 | |
Coding acc. to EN ISO 14119: | Low | |
Mechanical data
|
||
Housing design: | cylindrical | |
Detent present: | ||
cannot be mounted flush: | ||
Minimum installation distance (between two sensors): | 50 mm | |
Dimensions: | M30 x 37 mm | |
Material information
|
||
Cable material: | PVC | |
Housing colour: | schwarz | |
Nut material: | PBT | |
Housing material: | PBT | |
Environmental conditions
|
||
Shock resistance (Norm): | 30g / 11ms | |
Min. cable temperature range, fixed installation: | -25 °C | |
Min. cable temperature range, moving: | -5 °C | |
Protection class: | IP67 DIN EN 60529 | |
Operating temperature min.: | -25 °C | |
Max. operating temperature: | 75 °C | |
Max. cable temperature range, fixed installation: | 70 °C | |
Max. cable temperature range, moving: | 70 °C | |
Vibration resistance (Norm): | 10 - 55Hz | |
Installation
|
||
Torque for nuts: | 10 N m | |
Weight: | 60 g | |
Thread: | M30 | |
Mounting type: | Fastening nut | |
Installation: | arbitrary | |
Connection
|
||
Cable length: | 1 m | |
Number of strands: | 4 | |
Wire cross section: | 0.25 mm^2 | |
Cable type: | LiYY 4x0,25 | |
Cable colour: | grau | |
Approvals
|
||
Certified in accordance with: | ETL | |
CE label: | ||
Operating data
|
||
Possible actuators: | 30420000 |
17127118-5
€96.00
Electrical data
Switching principle:
magnetic
Protection class:
III
LED display:
No
Switching frequency:
5 Hz
Max. switching power:
3 W
Technology:
Reed
Assured switch-off distance (Sar):
23 mm
Series resistor:
22 Ohm
Actuation:
front
Pollution degree:
3
Assured switching distance (Sao):
7 mm
Minimum switching distance (S0 min):
3 mm
Min. switching voltage:
19.2 V DC
Contact form:
NO/NC
Max. switching voltage:
28.8 V DC
Safety-related characteristics
Mission time in years:
20 a
Structure acc. to EN ISO 13849-1:
Two-channel
B10d acc. to EN ISO 13849-1:
20000000
Type acc. to EN ISO 14119:
4
Coding acc. to EN ISO 14119:
Low
Mechanical data
Housing design:
cylindrical
Detent present:
cannot be mounted flush:
Minimum installation distance (between two sensors):
50 mm
Dimensions:
M30 x 37 mm
Material information
Cable material:
PVC
Housing colour:
schwarz
Nut material:
PBT
Housing material:
PBT
Environmental conditions
Shock resistance (Norm):
30g / 11ms
Min. cable temperature range, fixed installation:
-25 °C
Min. cable temperature range, moving:
-5 °C
Protection class:
IP67 DIN EN 60529
Operating temperature min.:
-25 °C
Max. operating temperature:
75 °C
Max. cable temperature range, fixed installation:
70 °C
Max. cable temperature range, moving:
70 °C
Vibration resistance (Norm):
10 - 55Hz
Installation
Torque for nuts:
10 N m
Weight:
60 g
Thread:
M30
Mounting type:
Fastening nut
Installation:
arbitrary
Connection
Cable length:
1 m
Number of strands:
4
Wire cross section:
0.25 mm^2
Cable type:
LiYY 4x0,25
Cable colour:
grau
Approvals
Certified in accordance with:
ETL
CE label:
Operating data
Possible actuators:
30420000
Documents and Downloads
Instructions