Safety sensor M12-8-pole indiv. A - 165ESK00J31
Part number:
Art. -No.
165ESK00J31
| Country of origin | Germany |
|---|---|
| Item weight | 0.06 kg |
| Customs tariff number | 85365019 |
Technical Data
|
165ESK00J31
€312.27
|
||
|
Electrical data
|
||
| Assured switching distance (Sao): | 8 mm | |
|---|---|---|
| Number of electronic safety outputs: | 2 | |
| Pollution degree: | 2 | |
| Rated switching distance (Sn): | 12 mm | |
| LED display: | three-coloured | |
| wurde angepasst (Number): | 30 | |
| Rated operating voltage (Ue): | 24 V | |
| Utilization category: | AC-12 / DC-13 | |
| Fuse operating voltage: | 1A fast | |
| Power consumption: | 24 W | |
| Start function: | automatic | |
| Current consumption per input: | 2.75 mA | |
| Overvoltage category: | II | |
| Voltage drop (Ud): | 0.75 V | |
| No-load current I0: | 30 mA | |
| Max. switching current at control output: | 0.05 A | |
| Coding variant: | individually coded | |
| Number of electronic control outputs: | 1 | |
| Max. switching current at safety output: | 0.4 A | |
| Switching frequency: | 3 Hz | |
| Switching principle: | electronic | |
| Rated insulation voltage (Ui): | 50 V | |
| Actuation: | arbitrary | |
| Contact form: | OSSD | |
| Cross-short detection: | ||
| Polarity reversal protection: | ||
| Hysteresis: | 2 mm | |
| EDM/start input: | ||
| Number of safety inputs: | 2 | |
| Active surface (Number): | 1 | |
| Short-circuit detection: | ||
| Assured switch-off distance (Sar): | 18 mm | |
| Technology: | RFID | |
| Readiness delay (tv): | 1000 ms | |
| Minimum switching distance (S0 min): | 0.5 mm | |
| Stabilised PELV/SELV power supply: | required | |
| Rated impulse withstand voltage (Uimp): | 1000 V | |
| Turn-on delay (ton): | 75 ms | |
| Internal electronic fuse: | ||
|
Safety-related characteristics
|
||
| Category acc. to EN ISO 13849-1: | 4 | |
| PL acc. to EN ISO 13849-1: | e | |
| SIL acc. to IEC 61508: | 3 | |
| PFHD according to IEC 61508: | 2,24x10^-9 1/h | |
| Mission time in years: | 20 a | |
| Coding acc. to EN ISO 14119: | High | |
| Structure acc. to EN ISO 13849-1: | Two-channel | |
| SIL CL acc. to IEC 62061: | 3 | |
| Hardware fault tolerance (HFT) according to IEC 61508: | 1 | |
| Type acc. to EN ISO 14119: | 4 | |
|
Mechanical data
|
||
| Free zone: | 50 mm | |
| cannot be mounted flush: | ||
| Dimensions: | 25 x 88 x 13 mm | |
| Housing design: | rectangular | |
| Actuation frequency: | 180 1/h | |
| Minimum installation distance (between two sensors): | 150 mm | |
|
Material information
|
||
| Housing colour: | grau, schwarz | |
| Cable material: | PVC | |
| Housing material: | PBT, PC | |
|
Environmental conditions
|
||
| Max. cable temperature range, moving: | 80 °C | |
| Max. cable temperature range, fixed installation: | 80 °C | |
| Protection class, connector: | IP67 / IP69K DIN EN 60529 | |
| Max. operating temperature: | 70 °C | |
| Min. cable temperature range, moving: | -5 °C | |
| Min. storage temperature: | -25 °C | |
| Continuous shock resistance (Norm): | 10 g / 16 ms | |
| Operating temperature min.: | -25 °C | |
| Shock resistance (Norm): | 30 g / 11 ms | |
| Min. cable temperature range, fixed installation: | -30 °C | |
| Air pressure: | 860 - 1060 hPa | |
| Max. storage temperature: | 70 °C | |
| Delta tmax: | 0.5 °C/min | |
| Relative humidity: | 5 - 85 % | |
| Protection class, housing: | IP67 DIN EN 60529 - IP6K9K ISO 20653 | |
| Vibration resistance (Norm): | 10 ... 55 Hz | |
|
Installation
|
||
| Weight: | 70 g | |
| Torque for fastening screws: | 0.7 N m | |
| Mounting type: | screwed | |
|
Connection
|
||
| Wire cross section: | 0.25 mm^2 | |
| Connector type: | M12x1 - 8 polig | |
| Cable length: | 0.15 m | |
| Cable type: | LiYY | |
| Number of strands: | 8 | |
| Cable colour: | grau | |
|
Approvals
|
||
| CE label: | ||
| Certified in accordance with: | EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.25 | |
|
Operating data
|
||
| Possible actuators: | 165EBK001 |
165ESK00J31
€312.27
Electrical data
Assured switching distance (Sao):
8 mm
Number of electronic safety outputs:
2
Pollution degree:
2
Rated switching distance (Sn):
12 mm
LED display:
three-coloured
wurde angepasst (Number):
30
Rated operating voltage (Ue):
24 V
Utilization category:
AC-12 / DC-13
Fuse operating voltage:
1A fast
Power consumption:
24 W
Start function:
automatic
Current consumption per input:
2.75 mA
Overvoltage category:
II
Voltage drop (Ud):
0.75 V
No-load current I0:
30 mA
Max. switching current at control output:
0.05 A
Coding variant:
individually coded
Number of electronic control outputs:
1
Max. switching current at safety output:
0.4 A
Switching frequency:
3 Hz
Switching principle:
electronic
Rated insulation voltage (Ui):
50 V
Actuation:
arbitrary
Contact form:
OSSD
Cross-short detection:
Polarity reversal protection:
Hysteresis:
2 mm
EDM/start input:
Number of safety inputs:
2
Active surface (Number):
1
Short-circuit detection:
Assured switch-off distance (Sar):
18 mm
Technology:
RFID
Readiness delay (tv):
1000 ms
Minimum switching distance (S0 min):
0.5 mm
Stabilised PELV/SELV power supply:
required
Rated impulse withstand voltage (Uimp):
1000 V
Turn-on delay (ton):
75 ms
Internal electronic fuse:
Safety-related characteristics
Category acc. to EN ISO 13849-1:
4
PL acc. to EN ISO 13849-1:
e
SIL acc. to IEC 61508:
3
PFHD according to IEC 61508:
2,24x10^-9 1/h
Mission time in years:
20 a
Coding acc. to EN ISO 14119:
High
Structure acc. to EN ISO 13849-1:
Two-channel
SIL CL acc. to IEC 62061:
3
Hardware fault tolerance (HFT) according to IEC 61508:
1
Type acc. to EN ISO 14119:
4
Mechanical data
Free zone:
50 mm
cannot be mounted flush:
Dimensions:
25 x 88 x 13 mm
Housing design:
rectangular
Actuation frequency:
180 1/h
Minimum installation distance (between two sensors):
150 mm
Material information
Housing colour:
grau, schwarz
Cable material:
PVC
Housing material:
PBT, PC
Environmental conditions
Max. cable temperature range, moving:
80 °C
Max. cable temperature range, fixed installation:
80 °C
Protection class, connector:
IP67 / IP69K DIN EN 60529
Max. operating temperature:
70 °C
Min. cable temperature range, moving:
-5 °C
Min. storage temperature:
-25 °C
Continuous shock resistance (Norm):
10 g / 16 ms
Operating temperature min.:
-25 °C
Shock resistance (Norm):
30 g / 11 ms
Min. cable temperature range, fixed installation:
-30 °C
Air pressure:
860 - 1060 hPa
Max. storage temperature:
70 °C
Delta tmax:
0.5 °C/min
Relative humidity:
5 - 85 %
Protection class, housing:
IP67 DIN EN 60529 - IP6K9K ISO 20653
Vibration resistance (Norm):
10 ... 55 Hz
Installation
Weight:
70 g
Torque for fastening screws:
0.7 N m
Mounting type:
screwed
Connection
Wire cross section:
0.25 mm^2
Connector type:
M12x1 - 8 polig
Cable length:
0.15 m
Cable type:
LiYY
Number of strands:
8
Cable colour:
grau
Approvals
CE label:
Certified in accordance with:
EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.25
Operating data
Possible actuators:
165EBK001
Documents and Downloads
Instructions